USE & OPERATION (CONTINUED)
CLEANING THE CARBON DUST FILTER AND HONEYCOMB COOLING MEDIA WITH ANTIBACTERIAL TREATMENT⁺
The appliance is supplied with a Carbon Dust Filter and Honeycomb Cooling Media with
Antibacterial Treatment⁺.
The Carbon Dust Filter and Honeycomb Cooling Media with Antibacterial Treatment⁺ are located
inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for
cleaning and maintenance.
Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank
and refill with fresh water, especially if the tank has not been cleaned in a long time.
The cleaning frequency for the Honeycomb media with Antibacterial Treatment⁺ depends on local
air and water conditions. In areas where the mineral content of water is high, mineral deposits
may build up on the Honeycomb Cooling Media with Antibacterial Treatment⁺ and restrict air
flow. Draining the water tank and refilling with fresh water at least once a week will help reduce
mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media with Antibacterial
Treatment⁺, the media should be removed and washed under fresh water. The media should be
cleaned every two months or sooner, depending on your needs.
For best results allow the Honeycomb Cooling Media with Antibacterial Treatment⁺ to dry after
each use by turning off the cool function 15 minutes before turning the unit off.
Removing the Carbon Dust Filter/ Honeycomb Cooling
Media with Antibacterial treatment⁺:
1.
Press the rear grill left and right buckle and
carefully pull out from the cooler.
2.
The Carbon Dust Filer is secured on the Rear Grill
by two Horizontal Bars which located on the top
and bottom part. Release the horizontal bars and
carefully pull out the Carbon Dust Filter and clean
with water as needed.
3.
To release the Honeycomb Cooling Media with
Antibacterial treatment⁺, remove the
Honeycomb Frame and pull the Honeycomb
Frame out of the unit.
4.
Remove the Honeycomb Frame and slide out the
Honeycomb Cooling Media with Antibacterial treatment⁺.
Replace or clean media with water and a damp cloth as
needed.
WARNING:
DO NOT operate the Air Cooler when the Rear Grill is
removed from the Air Cooler, or if there is a loose-fitting
Rear Grill. Doing so can cause serious injury or dangerous
electrical shock.
+ Antibacterial Honeycomb is up to 99%
A
Based on independent laboratory testing (report #WJ20182408), testing the antibacterial and cleaning function of the honeycomb
cooling pads against Escherichia coli (strain #ATCC 25922), Staphylococcus aureus (strain # ATCC 6538), Klebsiella Pneumonia
(strain # ATCC 4352) , as per testing standard JIS L 1902: 2015 Testing for antibacterial activity and efficacy on textile products &
GB 21551.2-2010 antibacterial and cleaning functions for household, and similar electrical appliances-Particular requirements of
material.
A
effective in killing certain types of bacteria through 48 hours of continuous use.