Pendulum Transport Lock
Low Battery Warning
Mount
Auto Shutoff
Calibration
IP Rating
Battery Type
Battery Life
Safety Class
Laser Diode
Beam Width
Operating Temperature
Level Accuracy
OOL Accuracy
Accessories
Remote Control
Type
1) The working range can be decreased by
unfavorable environmental conditions (e.g.
direct sun irradiation).
Please observe the article number on the type
Initial Operation
An accuracy check should always be carried
out before use.
Protect the tool against
WARNING
!
moisture and direct
sun light.
Do not subject the tool to extreme
temperatures or variations in temperature.
As an example, do not leave it in vehicles for
longer periods. In case of large variations in
temperature, allow the tool to adjust to the
ambient temperature before putting it into
At approximately 6 hours battery life remaining.
Flashing Laser – (ON 0.2 secs and OFF 0.2 secs for a
30 second period then ON until battery is exhausted,
Local service via 2 service ports on product
0.2 in @ 33 ft (5 mm @ 10 m), 100 lux,
± 3/16 in @ 100 ft (± 4.5 mm @ 30 m)
± 1/8 in @ 33 ft (± 3.0 mm @ 10 m)
plate of your tool. The trade names of the
individual tools may vary.
The tool can be clearly identified with the serial
number 8 on the type plate.
Operation
operation. In case of extreme temperatures or
variations in temperature, the accuracy of the
tool can be impaired.
Avoid heavy impact or dropping of the
tool. After heavy exterior impact on the tool,
an accuracy check should always be carried
out before continuing to work (see "Leveling
Accuracy").
Switch the tool off during transport. When
switching off, the leveling unit, which can be
damaged in case of intense movement, is
locked.
-8-
repeats on initial startup)
1/4-20 and 5/8-11
15 min. if not level, none if level
4 x AA cell Alkaline
68° F to -13° F (20° C to -25° C)
14° F to 122° F (-10° C to 50° C)
Laser Detector w/bracket, Case
Yes
IP55
50 hours
2
635 nm
N/A
Cone