Problem
Cause
The paint pattern is
The paint is too viscous or contaminated.
tailing.
The spray nozzle is plugged.
The spray nozzle is worn.
The spray nozzle is blocked (if fitted)
The inlet filter is clogged.
The inlet valve is worn or damaged.
In addition to the statutory warranty for this product, J. Wagner GmbH, based in 88677 Markdorf, Germany, grants you
a guarantee (device guarantee) of 36 months for this product. This guarantee is extended by a further 12 months if the
product is registered within 28 days of purchase on the Internet at https://go.wagner-group.com/3plus1.
The guarantee includes the free repair of defects which are demonstrably caused by the use of unsuitable
materials in the product's manufacture or by assembly errors, as well as the free replacement of faulty components
provided there are no guarantee exclusions.
The statutory material defect rights to which you as the purchaser are entitled for the intended purpose from the
time of handover of the purchased item are not restricted by the guarantee. The guarantee, along with your statutory
warranty rights, will expire if the device has been opened by persons other than authorised WAGNER service personnel.
The detailed guarantee conditions can be obtained on request from our authorised WAGNER partners (see website or operating
instructions) or in text form on our website:
https://go.wagner-group.com/hf-warranty-conditions
Warning
If the supply cord of this appliance is damaged, it must only be
replaced by a repair shop appointed by the manufacturer, because
special purpose tools are required.
The wires in this mains lead are coloured in accordance with the
following code:
green/yellow = earth
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifiying the terminals in
your plug, proceed as follows:
The wire which is coloured green and yellow must be connected
to the terminal in the plug which is marked with the letter E or by
the earth symbol or coloured green or green and yellow.
The wire which is coloured blue must be connected to the
terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured brown.
Should the moulded plug have to be replaced, never re-use the defective plug or attempt to plug it into a different 13 A socket.
This could result in an electric shock.
Should it be necessary to exchange the fuse in the plug only use fuses approved by ASTA in accordance with BS 1362. Only 13
Amp fuses may be used.
To ensure that the fuse and fuse carrier are correctly mounted please observe the provided markings or colour coding in the
plug.
After changing the fuse, always make sure that the fuse carrier is correctly inserted. With out the fuse carrier, it is not permissible
to use the plug.
The correct fuses and fuse carriers are available from your local electrical supplies stockist.
28
3 + 1 year guarantee on this WAGNER DIY product
blue = neutral
brown = live
Remedy
Thin or strain the paint.
Clean the spray nozzle and use the HEA filter set.
Replace the spray nozzle with a new nozzle.
Clean or replace the filter.
Clean the inlet filter.
Replace