User Information; Scope Of Delivery - Bosch Denoxtronic 2.2 Instrucciones De Funcionamiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
en
8 | Denoxtronic 2.2 | User information
2.

User information

2.1
Important information
Important information on working with the test adapter
can be found in the "Repair information", "Testers and
tools" and "Component preparation" Sections of the
separate Denoxtronic 2.2 ESI[tronic] repair instruc-
tions. These should be carefully studied prior to start-
up, connection and operation of the tester and must
always be heeded.
2.2
Safety instructions
All the relevant safety instructions are contained in the
"Safety instructions" Section of the separate Denoxtron-
ic 2.2 ESI[tronic] repair instructions. These instructions
should be carefully studied prior to start-up, connection
and operation of the tester and must always be heeded.
2.3
Intended use
The components of the tester set 0 986 610 840 and
the test adapter 1 687 023 723 included in this are
intended solely for testing and repair of the AdBlue sup-
ply module of type Denoxtronic 2.2.
!
Accidents and damage may result in the event of
non-compliance.
|
1 689 989 198
2014-02-25
3.

Scope of delivery

3.1
Tester set 0 986 610 840
Designation
Test adapter
AdBlue supply module connecting cable
Test control unit connecting cable
Test adapter operating instructions
3.2
Test adapter 1 687 023 723
Designation
Test adapter
Test adapter operating instructions
3.3
Accessories (to be ordered separately)
Designation
Voltage stabilizer
3.4
Description of test adapter
i
The following product description relates solely to
the test adapter 1 687 023 723. Pay attention to
Sec. 2.1 "Important information" in Sec. 2 "User
information".
Fig. 1:
Denoxtronic 2.2 test adapter
1 ON / OFF switch (IGN)
2 Switched 12 V power supply LED
3 12 V power supply ON button
4 24 V power supply ON button
5 Switched 24 V power supply LED
6 Circuit breaker
7 OBD plug connection
8 Connections for testing internal heating
9 Connecting cable 1 684 463 859 connection
10 Connecting cable 1 684 463 858 connection
11 Power supply (from external voltage stabilizer)
Article no.
1 687 023 723
1 684 463 858
1 684 463 859
1 689 989 198
Article no.
1 687 023 723
1 689 989 198
Article no.
1 687 022 873
Robert Bosch GmbH
Tabla de contenido
loading

Tabla de contenido