Air pump
The air pumps supply the stages 1 and 2 with
the oxygen required for the biological treat-
ment.
Checking the air pumps
When the air pumps are switched on, the sub-
strate in stage 1 and 2 must move evenly. (Mi-
nor dead spots in the corners do not matter).
If that is not the case, please check:
The hose connections between the air
•
pumps and the diaphragm aerators.
The air pumps' filters for contamination, if
•
necessary replace filters.
The diaphragm aerators for contamination /
•
obstruction, if necessary clean.
Connecting hose
1
Air hose
2
Connecting hose (transparent)
050608
Operating instructions AquaCycle 900
Filter
Warning!
Life threatening mains
voltage.
Before opening the air
pump, switch off main
switch and unplug
mains plug! Ensure that
it is not possible to ac-
cidentally re-activate
the supply voltage.
EN23