Safety notes
Area of application
The water recycling facility AquaCycle 900
serves exclusively to process shower and bath
water into high-quality service water. This water
can then be used to operate the toilet flush,
washing machine or to water the garden and
for cleaning purposes.
If the facility is operated and serviced as in-
tended, it supplies a constantly high water qual-
ity in accordance with the hygienic / microbi-
ological requirements of the EU Directive on
the quality of bathing waters dated 1975/12/08
as well as table 3 of the fbr instruction sheet
H201 dated January 2005.
The manufacturer and the company placing the
product on the market are not liable for dam-
ages resulting from misuse of the facility.
Requirements on the use
The service water network must be free of
•
micro leaks. Damages caused by micro
leaks exclude the manufacturer's guaran-
tee.
The facility must be installed and operated
•
in accordance with the state of the art. The
rules and standards DIN 1988 T1 to T8,
DIN 1986, DIN EN 1717, DIN 2403,
TrinkwV 2001 must be complied with.
The limits specified in the technical specifi-
•
cations may on no account be exceeded
(for technical specifications refer to the op-
erating instructions).
The following wastewaters may not be in-
troduced:
Kitchen wastewater,
•
Wastewater from washing machines and
•
dishwashers,
Wastewater containing faeces,
•
Wastewater mixed with dyes (paint resi-
•
dues, textile dyes and hair tinting lotions),
Wastewater from medicinal mud baths,
•
Heavily foaming wastewater.
•
EN6
Operating instructions AquaCycle 900
Area of application
Operators outside the Federal Republic of
Germany should consider the safety regula-
tions specified in this document as basis,
measure their implementation against locally
valid regulations and carry out any variations
that are necessary on-site.
Why you should read these instructions
These instructions contain important informa-
tion to operate the facility safely, appropriately
and economically. Consideration of these in-
structions is necessary to ensure the facility's
reliability and to avoid dangers.
If you require additional information or advice or
if any damages occur, please contact your con-
tractual partner or specialist dealer.
Dangers in case of non-compliance with
these instructions
Non-compliance with the safety instructions
may have dangerous consequences:
Danger for persons
•
Danger for the environment
•
Damage to the water recycling facility
•
Inspection and installation work
You as operator must ensure that all inspection
and installation work is carried out by an after-
sales service specialist or service technician.
Installation work must be carried out in accor-
dance with DIN 1988 T1 to T8 and DIN EN
1717.
050608