Hydraulic Connections; Gas Connection - Cointra CETI Bajo NOx Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CETI 12
V0DK96KAM
B32-C12-C22-C32-C42-C52-C62-C82-C92
II2R3R (ES, PT, FR)
II2H3P (PT)
II2Esi3P (FR)
II2Er3P (FR)
3B - G30 - 28-30 mbar
Qn (Hi)
=
Pn - Pmin
=
tmax =
65
°C
NOx 6 (< 56 mg/kWh)
0085 / 22
8
230 V ~ 50 Hz
34 W
Para instalación exterior en lugar parcialmente protegido
Temp. min.: -5 °C
MADE IN SPAIN
Fig. 1 - Rating plate

2.4 Hydraulic connections

Never support the water heater on water/
gas connections. Make the connections
in accordance with the dimensions and
connections in Section 4.1.
The inlets (water and gas) and water outlet are identified on the
bottom of the unit. All are 1/2".
64
EN
Ser. n.: 2219LE9000
max
-
min
23
-
4
kW
-
20.9
3.6
kW
pw
=
10
bar
D
=
10
l/min
H
O
2
430709
516618
2219LE9000
IPX4D
A73023711 - Rev. 00 - 2022-10
SYMBOL
DESCRIPTION
Symbol for the mains WATER inlet
Symbol for the mains GAS inlet
Symbol for the HOT WATER outlet
If the water hardness is over 25
(1
= 10 ppm CaCO3), the water must be trea-
°fH
ted to avoid possible deposits on the unit.

2.5 Gas connection

Before connecting, check that the unit
has been prepared for operation with
the fuel type and carefully clean all
the gas pipes to remove residues that
could impair the unit's operation. Make
this connection in accordance with the
dimensions and connections in Section
4.1.
1 . Connect the gas inlet (see Section 4.1) in accordance with
the applicable regulations of the country where the water hea-
ter is installed.
2 . Connect with a rigid metal pipe (connection to mains gas
supply) or a flexible pipe (approved, do not confuse with
flexible elastomer connection) for LPG installation, con-
tinuous stainless steel from the wall, adding a shut-off valve
between the installation and the unit (AS CLOSE TO THE
UNIT AS POSSIBLE).
3 . After completing the connection to the gas mains, check that
all gas connections are tight. For this purpose, a tightness test
must be performed. To avoid damage to the unit due to excess
pressure, leave the gas inlet valve closed.
Check that the supply pressure and the flow supplied in the unit
are those indicated for the unit's consumption.
See and check the Technical Data Table, Section 4.3.
CETI
°fH
Tabla de contenido
loading

Este manual también es adecuado para:

Ceti baixo noxCeti bas noxCeti low noxCeti serieCeti 12

Tabla de contenido