4.26. If for transportation reasons it is necessary to reduce the volume of the boiler, you can separate the boiler
body -hopper assembly. To do this you will need:
Remove backing hopper, top cover exchanger liner and the rear lining of the boiler.
Disconnect:
•
Motor reductors of cleaning system (ashtray drawer, burning pot and turbulators).
•
Safety thermostat.
•
Recirculating pump (power and control).
•
Display.
Unscrew the connection between the auger tube and the fuel fall tube.
Remove the 4 screws that secure the boiler body to the hopper.
Drawing 7
Drawing 8
48