3.
FUEL QUALITY.
Your boiler is designed to operate with wood pellets A1 quality.
ECOFOREST do not have any control on the quality of the fuel you use. For this reason, ECOFOREST cannot
guarantee the full output of your boiler nor the eventual premature aging or eventual damage of the gas outlet. The
fuel's minimum requirements are specified below:
Diameter (mm)
Length (mm)
Granulometry (mm)
Calorific value (Kcal/kg)
Ash (% mass)
Humidity (%mass)
Oils
Grill and/or specific strangler.
4.
INSTALLATION.
The below security distances and assembly diagrams are given for information only as an adaptation shall be
made depending on the norms in force regarding gas outlet, power, security minimum distances specific to
geographic areas.
It must be installed in a room with positive atmospheric pressure (minimum 5 pascals). Never make it
work in depression (airtight rooms or without the due air renovations).
The installation of the boilers must be done in the same way, for this reason, only the VAP30 model will be
exposed. In the same way, air inlets and water connections will be missed in all drawings indicates the minimum
security distances to be respected for their installation.
The power socket to which the boiler is plugged should meet the following requirements:
4.1.
Ground connection must comply with the specific applicable regulations.
4.2.
Differential switch with the correct amperage. It must comply with the specific applicable regulations (check
technical specifications of the boiler).
4.3.
Single-phase AC of 230/240V – 50Hz and pure sine wave.
4.4.
The plug must only be connected to a socket with the technical characteristics of the plug in question.
4.5.
Easily accessible power socket. If the power socket can't be accessed due to the characteristics of the
electrical installation, an all-pole disconnection switch must be installed.
4.6.
The power cable provided by ECOFOREST is 1.4m long; you might need a longer one. Always use a cable with
ground plug and with an equal or greater section. Make sure the power cable is not placed under the boiler
or close to hot or sharp surfaces that could damage it.
4.7.
Remove the packaging and the protective plastic.
4.8.
Remove the screws or bolts that fasten the boiler to the pallet and remove it.
4.9.
If our model has a plastic protection, it must be removed before starting it.
4.10.
Assembly of the burning pot cleaning system and electrical connection.
ELECTRICAL CONNECTION.
UNPACKING THE BOILER.
43
Pellets
6
5-25
— —
≥ 4300
< 1.5
< 12
— —
ORIGINAL