P RO B L EM
The LED flashes while the faucet is
running
The LED lights continuously and the
faucet does not run
The LED flashes while the faucet is
turned off
The water stream is unattractive
The flow of water reduces over time
Model 10101xx1: The water is not
warm enough or is too warm
Model 10106xx1: The water is not
warm enough or is too warm
Hot water bleeds into the cold supply
or vice versa
The faucet turns on unexpectedly
1
POS S IB L E C AU SE
The battery is low, but is still usable
The battery is dead
The faucet is in reduced range mode
The faucet has recently been installed
or serviced
Debris in the filters
The handle has not been justified
The temperature must be set
The check valve(s) is dirty or worn
Water droplets on sensor window
The lavatory is small or is highly reflec-
tive
A strong light source shines directly on
the sensor window
The solenoid is dirty or worn.
7
1
No immediate action is necessary, but
prepare to replace the battery.
Replace the battery
Normal operation, not a problem
No action needed: the stream will clear
after several uses
Follow the maintenance procedure
Justify the handle
Set the temperature
Replace the check valve(s) (item 96456000
on the parts sheet).
Dry the sensor window
Reduce the sensor range
Block the light source
Replace the solenoid.