Use the following procedure to change the
dosing of the oil pump:
1.
Pull out the power plug of the machine.
2.
Put down the cable where you can see it.
3.
Open the spring-loaded lower protective flap
(11) downward.
4.
Using the combination screwdriver (B), turn
the fillister head screw (10) counterclockwise
to loosen it.
5.
Open the cover and remove it.
6.
Using the combination screwdriver (B), turn
the hexagon socket screw (12)
counterclockwise to loosen it.
7.
Remove the intermediate cover (13) and the
oil tank (14).
20
Fig. 20: Opening the protective flap
Fig. 21: Removing the cover
Fig. 22: Removing intermediate cover and oil tank