Installing The Pump - Wilo Port 600 Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Port 600:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

English

5.2.8. Installing the pump

Observe the installation and operating instructions for the pump.
Pump types Drain MTC 32F39, Drain MTC 40, Rexa CUT, Drain
TS 40, Drain STS 40, Drain TC 40
CAUTION!
Stud bolts not removed from the hydraulics (Rexa CUT) can lead
to malfunctions and damage to the pump chamber wall.
Some parts of the fluid can accumulate on the stud bolts,
impairing free access to the intake area and macerator in the
pump.
The intake area and macerator in the pump must be kept free of
deposits.
Fig. 10: Preparing the pump
1
Pump
2
Discharge pipe
• Remove coarse contaminants in the pump chamber.
• Screw together the pump and discharge pipe outside the pump
chamber using the assembly materials supplied.
• Attach the connection cable to the horizontal section of the dis-
charge pipe using the cable tie supplied. The cable should run from
the pump to the cable tie with slight tension and with no slack.
• Close the shut-off device
• Suspend the chain from the discharge pipe (observing the separate
installation and operating instructions for the chain) and lower the
pump and discharge pipe into the pump chamber until the two cou-
plings have completely engaged with one another.
When lowering the pump, guide it in such a way that it does not
remain suspended on the pump chamber fittings.
NOTE:
For problem-free installation of the pump, it must be twisted later-
ally by around 90° so that it can be guided past the cross member.
• After suspending the pump, check that it is suspended freely and
with sufficient clearance from the pump chamber wall and that it
cannot touch the pump chamber wall.
• Detach the chain from the lifting equipment and suspend it from the
chain hooks in the pump chamber.
CAUTION!
Improper handling of the pump can lead to damage. Only sus-
pend the pump from the installed discharge pipe with a chain,
never from the connection cable.
Pump type Drain TMW 32
Fig. 11: Preparing the pump
1
Pump
2
Discharge pipe
• Remove coarse contaminants in the pump chamber.
• Screw the supplied discharge pipe outside the pump chamber in the
pressure port of the pump.
• Slide the angle piece with sliding sleeve on the discharge pipe.
• Place the pump with mounted discharge pipe and angle piece in the
centre of the sump floor. Screw the angle piece tightly to the shut-
off device.
52
3
Attachment for chain
4
Cable ties
3
Angle piece
4
Cable ties
Fig. 10: Drain MTC, Rexa CUT
4
2
Fig. 10: Drain TS, Drain STS, Drain TC
4
2
Fig. 11: Drain TMW
3
2
WILO SE 11-2015 V05 DIN A4
INSTALLATION
3
1
3
1
4
1
Tabla de contenido
loading

Tabla de contenido