Dimensions; Scope Of Delivery; Accessories; Transportation And Storage - Wilo Port 600 Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Port 600:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

TRANSPORTATION AND STORAGE

3.8. Dimensions

Fig. 2: Dimension drawing
The height dimensions increase by the upward protruding part of
the selected pump cover.

3.9. Scope of delivery

• Pump chamber with complete pipework, consisting of
• Discharge pipe with surface coupling, non-return valve and pres-
sure connection (version "E" without surface coupling and built-in
non-return valve in the pump)
• Shut-off device
• Cross member
• Chain (lifting equipment for pump installation)
• Installation materials for pumps
• Installation and operating instructions
NOTE:
For use as a pumping station, accessories are required that have to
be ordered separately.

3.10. Accessories

• Clamp bolting for connection to a PE discharge pipe
• Pump chamber extension (not possible for Port 600.1...E)
• Pump cover in classes A15, B125 or D400 (in accordance with
EN 124)
• Operating crank for shut-off device
• Flush connection with Storz C connection
• Flush connection extension
• Vacuum relief valve
• Level control using:
• Dynamic pressure bell, optionally with bubbling-through system
• Level sensor
• Float switch
• Tauchmotorpumpe (submersible pump)
• Switchgear (depending on level control device)
• Ex cut-off relay and Zener barrier as separate accessories for con-
nection of float switch or level sensor in potentially explosive areas
• Alarm switchgear
• Flash light
For further information, see catalogue.
4. Transportation and storage

4.1. Delivery

On delivery, check immediately that the shipment is complete and
undamaged. If any parts are damaged or missing, the transport com-
pany or the manufacturer must be notified on the day of delivery.
Claims made after this date cannot be recognised. Damage to parts
must be noted on the freight documentation.

4.2. Transport

Only the designated and approved fastening devices, transportation
and lifting equipment may be used for transportation. They must
have sufficient load bearing capacity and lifting force to enable the
pump chamber to be transported safely. When using chains, they
must be secured against slipping.
The personnel must be qualified for the tasks and must follow all
applicable national safety regulations during the work.
Installation and operating instructions Wilo-Port 600
English
43
Tabla de contenido
loading

Tabla de contenido