Referencias
Especificaciones generales
Sampling Frequency
Maximum Voltage Gain
Miscellaneous
Características eléctricas
Output impedance of signal generator: 150 Ω
DME8i-ES : Measured with DME8o-ES
DME8o-ES : Measured with DME8i-ES
DME4io-ES: Measured with DME4io-ES
Frequency Response
<DME8i-ES>
Input
Output
INPUT 1–8
OUTPUT 1–8
<DME8o-ES>
Input
Output
INPUT 1–8
OUTPUT 1–8
<DME4io-ES>
Input
Output
INPUT 1–4
OUTPUT 1–4
Gain Error
<DME8i-ES>
Input
Output
INPUT 1–8
OUTPUT 1–8
External Clock
Internal Clock
Gain: –60dB, RL:600Ω, 64dB INPUT to OUTPUT
Power Consumption
Dimensions (HxDxW)
Net Weight
Temperature range
Include Accessories
fs=48kHz@20Hz–20kHz, reference to the nominal output level @1kHz
fs=96kHz@20Hz–40kHz, reference to the nominal output level @1kHz
RL
input level: –60dBu, GAIN: –60dB
600Ω
input level: +10dBu, GAIN: +10dB
RL
600Ω
input level: +10dBu, GAIN: +10dB
RL
input level: –60dBu, GAIN: –60dB
600Ω
input level: +10dBu, GAIN: +10dB
@1kHz
RL
input level: –60dBu, GAIN: –60dB
→ output level: +4.0dBu (typ.)
600Ω
input level: +10dBu, GAIN: +10dB
→ output level: +4.0dBu (typ.)
Normal Rate: 44.1/48 kHz (±0.1%)
Double Rate: 88.2/96 kHz (±0.1%)
Normal Rate: 48 kHz (±50ppm)
Double Rate: 96 kHz (±50ppm)
40W
44x361x480 mm
4.5kg
operating: 5 to 40˚C
storage: –20 to 60˚C
AC Power cord, Mini Euro plug(16P)x1, Euro plug(3P)x8,
Owner's Manual, Rubber feetx4
CONDITIONS
CONDITIONS
CONDITIONS
CONDITIONS
DME8i-ES/DME8o-ES/DME4io-ES Manual de instrucciones
MIN
TYP
MAX
UNITS
–1.5
0.0
+0.5
dB
–1.5
0.0
+0.5
dB
MIN
TYP
MAX
UNITS
–1.5
0.0
+0.5
dB
MIN
TYP
MAX
UNITS
–1.5
0.0
+0.5
dB
–1.5
0.0
+0.5
dB
MIN
TYP
MAX
UNITS
–2.0
0
+2.0
dB
–2.0
0
+2.0
dB