Product Description; Models And Contents Of The Package; Technical Data - Dea PASS24NET/N/V Instrucciones De Uso Y Advertencias

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35

2 PRODUCT DESCRIPTION

Models and contents of the package

The name PASS N identifi es a series of electromechanical barriers with different characteristics with regard to the motor power supply,
the speed of movement and the maximum length of the boom. All motorized models foresee the use of advanced control units (NET series)
equipped with anti-crush sensor, built-in 433 MHz radio receiver, speed adjustment and slow down during opening and closing.
The PASS N model is intended for residential use or small car parks.
The choice of barrier depends on the width of the access area and the expected duty cycle.
The DEA System complementary accessories are indicated in the table "PRODUCT ACCESSORIES" (pag. I-7).
PASS N vehicular barriers are composed by an electromechanical operator which puts in rotation the boom directly, while the balance
is assigned to a compression spring.
The automation together with the control panel, is enclosed in a painted sheet metal box (or steel) with a lockable door.
Transport
PASS N is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information
that may be provided on the same box for storage and handling.

3 TECHNICAL DATA

Motor power supply voltage (V)
Absorbed power (W)
Type of boom used
Duty cycle (cycles/hour)
Maximum n° of operations in 24 hour
Operating temperature range (°C)
Opening time 90° (s)
Weight of product with package (Kg)
Sound pressure emitted (dBA)
Protection degree
Power supply (V)
Rated power transformer (VA)
Fuse F2 (A) (transformer)
Batteries
Fuse F1 (A) (batteries input)
24V operators outputs
Warning: The above values are calculated by taking the maximum power supplied by the respective processors. In absolute terms, the maximum cur-
rent from each output must not exceed 10A.
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
OPERATOR
PASS24NET/N/V
Refer to Table on page I-6
290
2,2 s
CONTROL BOARD
NET24N
230 V ~ ±10% (50/60 Hz)
(24V_AUX + 24V_ST = max 200mA)
24V
HCS fi x-code - HCS rolling code - Dip-switch
PASS24NET/N/L
24 V
105
140
800
-20÷50 °C
6 s
41
< 70
IPX4
150 VA (230/22V)
2A
2x 12V 4A
15A
2x 5A
24 V
24 V
max 15 W
max 5W or max 1 art. 110
24 V
max 15W
-20÷50 °C
433,92 MHz
100
PASS N
PASS24NET/N/VR
240
2,8 s
EN-3
Tabla de contenido
loading

Este manual también es adecuado para:

Pass24net/n/lPass24net/n/vr

Tabla de contenido