SAFETY CRITERIA
1 Attention: before beginning any kind of procedure of installation
is absolutely necessary to read all this manuall.
2 Test/Control that the performances of the actuator auswer to
your installation needs.
3 Besides control that:
• The gare hinges are in good conditions and perfectly fattened.
• The gate has mechanicall stops in the opening and the closing.
INSTALLATION ADVICE
Connections:
See the "Scheme functional " and refer to the control central
scheme.
• The electric cable in the exit from the actuator must be tight,
but do an ample curve towards the bottom in order to avoid the
reflux in the inside of the actuator itself. (Fig. Q)
• The adjustment must be effected when the device has no
power supply.
Foresee a omnipolar breaking device near to the apparatus (the
contact must measure at least 3 mm).
Always protect the power supply using a 6A automatic switch,
or a 16A single-phase switch fises.
• The power supply lines the motors, to the control unit and the
connection lines to the outfits must be separated to avoid trou-
bles which could generate problems in the installation working.
• Any outfits (of control or safety) eventually connected to the
control unit must be tension free.
Spare parts:
Use esclusively original spare parts.
• The batteries should be put with industril waste and not with
domestic refuse. (Law n. 475/88).
Installation:
• In order to use correctlythe product and to exclude the possibi-
lity of injury or damage, refer to the "Generals" page enclosure,
which is an integrated part of this manual.
The use of this equipment must be in observance of the safety
standards in force in the country where it is installed, as well as
the standards governing proper installation.
• Together with this manual is provided a label showing manu-
facturer's name and product reference: please stick it insight on
the equipment for future reference.
Warranty:
• The warranty supplied by the manufacturer becomes void in
the event of interference, carelessness, improper use, lightening
damage, power surcharges or use by unqualified personnel.
• The warranty will also become in the following event: Failure to
observe the instructions given in the manuals supplied with the
product.
The application of any part in a manner differing from that pro-
vided for current legislation or the use of spare parts which are
unsuitable and/or not approved by manifacturer.
The manifacturer cannot be helb responsible for damages due
to impropre or unresonable use.
INSTALLATION INSTRUCTION SEQUENCE
1 Before the installation, analyse the risks referring to the chapter
"Generalities" of this instructions manual, fill the technic table
and eliminate the risks noticed.
In case of more risks, foresee the installation with security system.
2 Test the security laws of the "Security Criteria".
3 Identify the right actuator and left actuator.
4 Control all the components.
5 Identify the fixing point on the gate and then on the pillar.
6 Fix the"Anchor plate" at the little pillar.
7 Fix the gear motor to the "Anchor plate".
8 Unlock the actuator.
9 Fix the articulated arm.
10 Fit the support S3 to the gate
11 Connect the wires according the "Functional swing gate scheme".
12 Connect the control unit and all the accessoires
13 Program the radio receptor
14 Program working times
In case of badworking, see the "Anomalies and advises".
If you do not find any solution call the nearest Assistence centre.
8
GB
ELECTRO LOCK
Please notice that the electric lock must be installed on the swing
that opens first and must be connected with the terminal board of
the control unit.
Position of the electric lock: (Fig. B)
Position 1: Lock between the wings
(in this case is necessary to use the bolt RT15 on the second wing).
Position 2: Lock in the floor (in this case the utilisation of the bolt
is not necessary).
Remember to remove the lock or at least block the lock in opening
position and take away all the bolts of lock.
RIGHT OR LEFT ACTUATORS
The actuators are supplied in Right or Left version.
Right or left are established looking the gate from the side where
the actuators are installed, if the hinges are on the right the actuator
is right, if they are on the left the actuator is left.
Conseguentely the actuator must be installed with the exit pin,
positioned in the hinges of the gates.
DETERMINATION OF FIXING MEASURES
To determinate the clamping point it is necessary pay attention to
this:
A = 300 mm (Fig. C)
Maximum dimension between the axis of the gate and the edge
of the pillar.
B = 30 mm (Fig. C)
Maximum dimension from the anchor plate to the edge of the
pillar.
(to avoiod the possible brake of the edge)
D = 14 mm (Fig. F)
Vertical distance from the clamping point of the clamp S3 on
the gate, to the anchor plate on the little adge.
Gate fixed in the middle of the pillar (Fig. D)
In this case the maximun al opening corner of the gate is 90°.
Gate fixed on the edge of the pillar (Fig. E)
In this case the gate can be opened with a corner greater than 90°.
Pay attention to this: growing the distance of the actuator from the
edge of the pillar measure B, the opening angle of the gate grows.
HEIGHT INSTALLATION
Calculate the height of the actuator installation according to the
gate's shape and the fastening possibility.
a) If the gate has a big structure you can position it at any height
with no limits.
b) If the structure is light it necessary to put the operator as much
as possible to the centre of the gate (in heigt).
Position 1 Central beam of the gate
Position 2 Stiffen of the gate
FIXING THE ANCHOR PLATE
To dawel or to soldel the anchor plate on the little pillar near to the
gate, paynig attention to the quotes indicate above.
In case of clamping with expanding loose pieces, use metallic loose
pieces Ø 13 mm and consider that the loose piece has to be
positioned at 30/35 mm distant from the edge of the little pillar to
avoid the possibility of broke.
In case of wolling pillar use chemichal loose pieces, or resine loose
pieces, or a connectly wolled clamp.
It is possible to use the plate, in two different ways, for right or left
actuator, according to the particulary exigences. (Fig. H / I)
(Fig. A)
(Fig. G)
Advantage - rev. 14_06_2022