Fault Diagnosis - Stanley AV 50 Manual De Instrucciones Y Servicio

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

E N G L I S H

8. FAULT DIAGNOSIS

SYMPTOM
Placing Tool will not
operate
Trigger Switch 7 does
not function
Pump running but
placing tools does not
function
Placing tool operates
erratically and/or
does not achieve full
pressure
Pump builds full
pressure, but pintail
does not break
22
POSSIBLE CAUSE
Inoperative pump unit
Faulty Quick Couplers 10 and 11
Trigger Control Cable 14 not
connected correctly
Damaged Trigger Switch 7 or
Control Cable 14
Pump in local mode
Trigger Switch 7, Control Cable 14
or connector damaged
Hydraulic Hoses not connected
Low oil level
Placing tool external oil leak
Hose Assembly external oil leak
Pump internal/external oil leak
Low or erratic hydraulic pressure
supply
Worn or damaged hydraulic seals
in placing tool
Worn or damaged hydraulic
sealing surfaces in placing tool
Valve Rod 16 sealing surface worn
Pump internal/external oil leak
Breakload greater than placing
tool capacity at full pressure
Flow to placing tool blocked
Pump pressure relief value set too
low
Pull grooves on fastener pintail
stripped
Improper tool operation
REMEDY
Check pump power supply and refer to
pump unit instruction manual
Replace Quick Couplers
Check Control Cable is correctly
connected at pump and placing tool
Replace Trigger Switch and/or Control
Cable
Refer to pump instruction manual
Replace Trigger Switch and/or Control
Cable
Check for correct connections at pump
and placing tool
Ensure placing tool is filled with oil and
correctly primed
Refer to pump instruction manual
Inspect placing tool – replace worn or
damaged components
Inspect Hose Assembly – ensure hose
connections are tight and/or replace
damaged hose connectors
Refer to pump instruction manual
Refer to pump instruction manual
Inspect placing tool – replace worn or
damaged seals
Inspect placing tool – replace worn or
damaged components
Inspect Valve Rod and replace if worn or
damaged
Refer to pump instruction manual
Refer to placing tool specification
Check Quick Couplers 10 and 11 for full
engagement
Adjust pressure relief valve settings –
refer to pump instruction manual
See symptom on page <PŘ>
O R I G I N A L I N S T R U C T I O N
PAGE REF.
16
10
16
16
10
10
13 - 16
16
13 - 16
13 - 16
14 & 16
7
10
11
11
Tabla de contenido
loading

Este manual también es adecuado para:

73435-02000

Tabla de contenido