9. FAULT DIAGNOSIS

M
SYMPTO
Placing Tool will not
operate
Trigger Switch 7 does not
function
Pump running but
placing tools does not
function
Placing tool operates
erratically
Pump builds full
pressure, but pintail does
not break
Placing tool Piston 1
will not return
20
POSSIBLE CAUSE
Inoperative pump unit
Faulty Quick Couplers 10 and 11
Trigger Control Cable 14 not
connected correctly
Damaged Trigger Switch 7 or
Control Cable 14
Pump in local mode
Trigger Switch 7, Control Cable
14 or connector damaged
Hydraulic Hoses not connected
Low oil level
Placing tool external oil leak
Hose Assembly external oil leak
Pump internal/external oil leak
Low or erratic hydraulic pressure
supply
Worn or damaged hydraulic seals in
placing tool
Worn or damaged hydraulic
sealing surfaces in placing tool
Pump internal/external oil leak
Breakload greater than placing tool
capacity at full pressure
Flow to placing tool blocked
Pump pressure relief value set too
low
Pull grooves on fastener pintail
stripped
Improper tool operation
Return flow restricted or blocked
Hydraulic Hoses not connected
Pump valve malfunction
REMEDY
Check pump power supply and refer to
pump unit instruction manual
Replace Quick Couplers
Check Control Cable is correctly connected
at pump and placing tool
Replace Trigger Switch and/or Control
Cable
Refer to pump instruction manual
Replace Trigger Switch and/or Control
Cable
Check for correct connections at pump and
placing tool
Ensure placing tool is filled with oil and
correctly primed.
Refer to pump instruction manual
Inspect placing tool – replace worn or
damaged components
Inspect Hose Assembly – ensure hose
connections are tight and/or replace
damaged hose connectors
Refer to pump instruction manual
Refer to pump instruction manual
Inspect placing tool – replace worn or
damaged seals
Inspect placing tool – replace
worn or damaged components
Refer to pump instruction manual
Refer to placing tool specification
Check Quick Couplers 10 and 11
for full engagement
Adjust pressure relief valve settings – refer
to pump instruction manual
See symptom on page 20
Check Quick Couplers 10 and 11 for full
engagement and/or fault
Check for correct connections at pump and
placing tool
Refer to pump instruction manual
PAGE REF.
14
9
14
14
9
9
12–14
14
12–14
12–14
6
8
10
10
9
9