6. Connect the Wiring - Hardwired
WARNING: Risk of electric shock. Grounding is required. A qualified electrician should make all electrical
connections.
NOTE: Follow this step when hardwiring your toilet. If you are using the plug-in cord, continue to the "Check
Operation" section.
Route the branch circuit supply conductors through UL Listed flexible conduit from the junction box or other
approved enclosure to the field wiring compartment at the rear of the toilet as shown and in accordance with local
electrical installation codes.
Using a suitable strain relief, connect the Line, Neutral, and Ground wires to the electrical connections as shown.
Install the electrical connection cover with the four screws.
Install the electrical panel cover with the two screws.
Kohler Co.
Neutral (White)
Line (Black)
9
Ground (Green)
Qualified electrician
to provide suitable
strain relief.
1295780-2-B