Daily Operating; Operating The Handpallet; Self-Acting Display Test - Kaiser+Kraft 614 627 Manual De Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 103
5.
Operating KPZ 71
5.1

Daily operating

Before using, please check the device for its working condition, is it ready for handling and free of visible
damages, specifically on wheels and forks.
Please check the battery and follow electronic and charger guidelines.
While handling the device not a lot of effort should required. However, if noticing any doubts would
occurred, please contact the manufacturer or dedicated dealer.
5.2

Operating the handpallet

KPZ scales are endowed with easy operating mechanism to weightlifting, neutrality and to lower the
work lift.
Weightlifting
Lower down the choosing arm. Using drawbar to pump to reach required height.
Neutrality
Pull up choosing arm reaching the centre position. Choke pump and thrill are switched off.
Lower the work lift
Choosing arm pull up and hold. Forks will lower down. Realize the choosing arm, which automatically
return to neutral position.
5.3
Engine warming-up
It is recommended to begin weighting after 10 minutes from the switching on the device.
5.4

Self-acting display test

After switch on the scale, automatically will begin self-acting display test. Visible counting from 99999 to
000000. Please pay attention to all signs and symbols on the display which are showing up on full screen,
to avoid receiving an incorrect values. After displaying zero the scale is ready to use. If scale is not
showing „0" then please press 0 to resetting the scale.
5.5
Locating the load
The goods should be always placed on the pallet, on the pallet with net or in similar containers in central
point of forks.
The load can not sticking out of the pallet. Maximum capacity can not be overloaded.
Sudden, strong impingements can damage load cells of the scale. Avoiding strong impingements extend
longevity of load cells. To reassure long-lasting weighting values is not recommended to leave the load
on the forks for longer periods
(example: over night), because it can influence on effectiveness load cells.
5.6
Reasons for potential incorrect weighting values:
The scale can show an incorrect weighting values when:
-
Under the scale or between the forks is an item or some contamination.
-
After switching on, during functional test the scale is/ or will be loaded.
-
Weighting goods are placed just right next to the control panel box, on the ground or lean on
other subjects.
-
Incorrect charging.
-
Cable connection is break down between control panel and load cells
GB
GB - 7
Tabla de contenido