Kärcher KMR 1250 BAT Manual Del Usuario página 26

Ocultar thumbs Ver también para KMR 1250 BAT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Fault
Machine does not move
Control lamp "drive error" blinks
Machine is not sweeping properly
Dust gathers in the machine
High emptying does not function
Roller brush or side brush does not turn. Remove belts or cords from roller brush or side brush
Blower does not rotate
Troubleshooting
Remedy
Sit on the driver seat, the seat contact switch gets activated
Charging or replacing battery
Check fuse, replace if required
Check automatic fuse and reset if required
Set the gear lever to "fast" or "slow".
Inform Kärcher Customer Service.
Observe switch-on sequence
Inform Kärcher Customer Service.
Check roller brush and side brushes for wear, replace if necessary.
Check function of bulk waste flap
Empty waste container
Check sealing strips for wear, adjust or replace as required
Adjust roller mirror
Check drive belts of the roller brush and side-brushes
Check dust filter, clean or replace
Inform Kärcher Customer Service.
Switch on blower
Check suction fan drive belt
Check dust filter, clean or replace
Check sealing strips for wear, adjust or replace as required
Replace fuse
Switch is defective; inform Kärcher Customer Service
Hydraulic unit is defective; inform Kärcher Customer Service
Inform Kärcher Customer Service.
Check drive belts of the roller brush and side-brushes
Check fuse, replace if required
Inform Kärcher Customer Service.
Lower waste container completely
Check blower end switch
Check fuse, replace if required
Inform Kärcher Customer Service.
EN
-
10
25
Tabla de contenido
loading

Este manual también es adecuado para:

1.091-102

Tabla de contenido