Gas Valves Maintenance And Cleaning - Becken S 5050 IX A Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

In this position, remove the knob of the tap.
With a screwdriver adjust the taps screw until the flame is conveniently
regulated to the low position and stable.
Reassemble the knob and pass quickly from the Full On Position to the Low
Position, several times, to ensure that the flame remains stable.
f) After connecting the unit, check for gas leaks with a soap and water solution. Never
Use A Flame.
g) Near the inlet gas connection, place a label indicating the type of gas for which the
appliance is now prepared. "Appliance prepared for..."

2.3. Gas Valves Maintenance and Cleaning

If the gas valve is hard to turn, do not force it. It might need lubrication.
This operation must be executed always by qualified and authorised personnel.
To access the valves, pull the burner heads and remove the cooking top.
To lubricate the valves, follow these instructions:
With a screwdriver, remove the cover.
Pull the cone out of its housing.
Clean the cone with a dry lint-free cloth.
Lubricate the cone carefully, with recommended grease (Molykote, Staburgs
N32, Rocol HT, Optitemp HT2 EP), and take off the excess grease to avoid
obstructing the gas passages.
Introduce the cone and the spring and screw the cover.
Turn the cone several times, to ensure it is not stuck.
Check for gas leaks, with the tap opened and closed. Never use a flame.