AdJUSTINg THROAT PLATE
disconnect the machine from the power
source!
Make sure that the throat plate (A) is always
level with the table.
Place a straight edge (B) Fig. 30 across the table at both
ends of the throat plate (A).
To adjust, loosen the screw (D) Fig. 30 and turn the adjusting
screws (C) Fig. 30 with the supplied hex wrench.
INSTALLINg THE TOOL HOLdERS
disconnect the machine from the power
source!
1.
Install the fence holders (A) Fig. 31 using four 1/4-20 x
3/8" (9.5 mm) round head tap screws.
2.
Install the wrench hook (B) using two M4 x 8 mm self-
tapping screws.
INSTALLINg dUST PORT
disconnect the machine from the power
source!
Attach the dust port (D) Fig. 33 using four 1/4-20 x 3/8"
(9.5 mm) self-tapping screws.
ASSEMBLINg THE MITER gAUgE
disconnect the machine from the power
source!
Place a flat washer (A) Fig 34 on the threads of the miter
gauge lock handle (B). Thread the handle into the hole (C)
in the miter gauge bar.
Insert the plate (D) (Inset) into the miter gauge slot (E). Slide
the miter gauge on the saw table.
B
d
C
C
Fig. 34
16
A
C
Fig. 30
Fig. 31
B
A
d
Fig. 33
d
E
A
B