Inspect Muffler And Spark Arrester; Valve Clearance; Storage - Generac XT8000EFI Manual Del Usuario

Ocultar thumbs Ver también para XT8000EFI:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Battery Charger Fuse Replacement
The charging port is protected by a 3.0 Amp
replaceable in-line fuse. If the charger is not
charging the battery, check the fuse.
NOTE: To order a new fuse, contact the near-
est IASD at 1-888-GENERAC (1-888-436-
3722).
The battery charger fuse is located behind the
control panel.
Inspect Muffler and Spark
Arrester
NOTE: It is a violation of California Public
Resource Code, Section 4442, to use or oper-
ate the engine on any forest-covered, brush-
covered, or grass-covered land unless the
exhaust system is equipped with a spark
arrester, as defined in Section 4442, main-
tained in effective working order. Other states
or federal jurisdictions may have similar laws.
Contact original equipment manufacturer,
retailer, or dealer to obtain a spark arrester
designed for exhaust system installed on this
engine.
NOTE: Use ONLY original equipment replace-
ment parts.
Inspect muffler for cracks, corrosion, or other
damage. Remove spark arrester, if equipped,
inspect for damage or carbon blockage.
Replace parts as required.
Inspect Spark Arrester Screen
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces could
result in severe burns or fire.
1. Loosen clamp (A) and remove screw. See
Figure
4-6.
2. Inspect screen (B) and cone (C). Replace
if torn, perforated or otherwise damaged. If
screen is not damaged, clean with com-
mercial solvent.
3. Replace spark arrestor cone (C) and
screen (B). Secure with clamp and screw.
Figure 4-6. Spark Arrestor Screen
Owner's Manual for Portable Generator
WARNING
C
B

Valve Clearance

Important: Please contact an Independent
Authorized Service Dealer for service assis-
tance. Proper valve clearance is essential for
prolonging the life of the engine.
Check valve clearance after the first fifty-hours
of operation. Adjust as necessary.
• Intake — 0.15 ± 0.02 mm (0.006" ± 0.001"
inch)
• Exhaust — 0.20 ± 0.02 mm (0.008" ±
0.001" inch)

Storage

General
It is recommended to start and run the genera-
tor for 30 minutes, every 30 days. If this is not
possible, refer to the following list to prepare
unit for storage.
• DO NOT place a storage cover on a hot
generator. Allow unit to cool to room tem-
perature before storage.
• DO NOT store fuel from one season to
another unless properly treated.
• Replace fuel container if rust is present.
Rust in fuel will cause fuel system prob-
lems.
(000108)
• Cover unit with a suitable protective, mois-
ture resistant cover.
• Store unit in a clean and dry area.
• Always store generator and fuel away from
heat and ignition sources.
Prepare Fuel System for Storage
Fuel stored over 30 days can go bad and
damage fuel system components. Keep fuel
fresh, use fuel stabilizer.
If fuel stabilizer is added to fuel system, pre-
pare and run engine for long term storage.
Run engine for 10-15 minutes to circulate sta-
bilizer throughout fuel system. Adequately
prepared fuel can be stored up to 24 months.
1. Change engine oil.
2. Remove spark plug.
A
3. Pour tablespoon (5-10cc) of clean engine
oil or spray a suitable fogging agent into
cylinder.
000586
DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Store fuel in a well
ventilated area. Keep fire and spark away. Failure to
do so will result in death or serious injury.
WARNING
Risk of Fire. Verify machine has properly
cooled before installing cover and storing
machine. Hot surfaces could result in fire.
(000143)
(000109)
17
Tabla de contenido
loading

Tabla de contenido