Electrical Connection

The cooktop is equipped with a flexible metal conduit encasing 3 wires ready for
connection to a grounded power supply.
1. Disconnect power.
2. Remove junction box cover if it is present.
3. Connect the flexible cable conduit from
the cooktop to the junction box using
a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector
if present.
5. See next page to complete installation
for your type of electrical connection.
208/240 V, 60 Hz, 16 A fuse rating
Black wire: connect to L1 (hot)
Red wire: connect to L2 (hot)
Green/Yellow wire: connect to GND
(ground)