CONNECTION TO THE POWER SUPPLY
Installation diagram
Model Supply Voltage / Frequency Number of phases
7380645
7381645
7381245
7382645
7383645
7384645
The appliance may ONLY be connected by an authorized qualified technician.
•
Electric system protection should comply with all relevant regulations.
•
The connection clips can be accessed when the connection clip covers are opened /
•
removed.
Before connecting the appliance, make sure the voltage indicated on the rating plate is
•
consistent with the voltage in your home network. Connection voltage should be checked
by a qualified technician using a corresponding measuring device!
The rating plate with basic information is attached on the lower side of the appliance.
•
In order to make a fixed connection to the mains, insert an all-pole circuit breaker
•
between the appliance and the mains. This device shall have a contact separation in all
poles, providing full disconnection under overvoltage category III conditions.
The current conducting and isolated parts must be protected from any possibility of direct
•
contact.
Before any intervention, disconnect the appliance from the power mains. Connect the
•
appliance in compliance with the electric connections diagram supplied; make sure the
relevant network voltage is observed!
The ground wire should be connected to the clip indicated by the earth symbol.
•
The mains cable should be fed through the fastening clip which protects it from being
•
accidentally pulled out.
After connecting the appliance, turn on all cooking zones / heaters for approximately
•
three minutes to make sure they are operating correctly.
Incorrect connection may destroy parts of the appliance, making the warranty void!
•
Connection cable on the back of the appliance should be led in such way that it DOES
•
NOT touch the appliance back wall, as this part will get very hot during operation.
The appliance is generally configured to the maximum available power, shown in the
•
technical data table. It's possible to set an operating mode with power limitation. This
setting can be made at the time of installation or subsequently by a specialized
technician. See chapter on power limitation setting.
Use cables type: H05V2V2-F
LIVE
L1 – L2 – L3
EARTH
NEUTRAL
N1 – N2
220-240 V~ 50/60 Hz
220-240 V~ 50/60 Hz
380-415 V ~ 50/60 Hz
220-240 V~ 50/60 Hz
380-415 V ~ 50/60 Hz
BROWN – BLACK - GREY
GREEN / YELLOW
BLUE
Power cable section
1 phase + N
3 x 2,5 mm2
1 phase + N
3 x 4 mm2
2 phases + N
4 x 2,5 mm2
1 phase + N
5 x 2,5 mm2
3 phases + N
5 x 1,5 mm2
25
Connection