Modello/Ø
Tensione
Model/Ø
Voltage
Modèle/Ø
Tension
Modelo/Ø
Tensión
24 Vdc
24 V/50 Hz
110 V/50-60 Hz
230 V/50-60 Hz
*Per cicli/ora con tempi ON/OFF differenti da quelli indicati contattare il nostro ufficio tecnico
*For cycles/hour with different ON/OFF times than those indicated, contact our technical department
*Pour les cycles/heure avec des temps ON/OFF différents de ceux indiqués, contacter notre service technique
*Para ciclos/hora con tiempos ON/OFF diferentes de los indicados, consulte a nuestro departamento técnico
Parameter
Hardware Failure Tolerance - HFT
Common Cause Failure - CCF in points
Safe Failure Fraction - SFF in %
Expected Lifetime Cycles - B
Expected Lifetime - T
[years]
10d
Probability of Dangerous Failures - PFH
Performance Level - PL
Safety Integity Level - SIL
Mean Time to Dangerous Failure - MTTF
Designed operating cycles
(According to EN 161)
from 100.000 to 200.000
depends on diameter
JV(Q-R-S-T)-1-3-6
Tabella 2b - Table 2b - Tableau 2b - Tabla 2b
Bobine - Coils - Bobines - Bobinas
Codice bobina
Coil code
Code bobine
Código de la bobina
BO-0355JSDC
BO-0355JSAC
BO-0365JSAC
BO-0375JSAC
Tabella 3 - Table 3 - Tableau 3 - Tabla 3
10d
[1/h]
D
[years]
D
DESIGNED LIFETIME
Timbratura bobina
Coil stamping
Energy
Timbrage bobine
Saving
Marcaje de la bobina
BO-0355JSDC
YES
24 VDC
BO-0355JSAC
YES
24 V/50 Hz
BO-0365JSAC
YES
110 V/50-60 Hz
BO-0375JSAC
YES
230 V/50-60 Hz
SIL LEVEL
34
Madas Technical Manual - 1|1.5bJ - REV. 0 of 1
Potenza assorbita
Cicli/ora*
Absorbed power
Cycles/hour*
Puissance absorbée
Cycles/heure*
Potencia absorbida
Ciclos/hora*
68 VA / 18 VA
~ 90
ON=10s
OFF=30s
77 VA / 23 VA
89 VA / 25 VA
Value
0
75
65%
251278
87
1.33E-07
d
2
860
Time (years)
10
Aug 2019
st