Tabla de contenido
Idiomas disponibles

Idiomas disponibles

USER'S MANUAL PRODIG-1+.

3.1.3 Battery Charging

To fully charge the battery with the PRODIG-1+ switched off, connect the mains
adapter to the external power supply input
adapter to the mains. The charging process starts automatically. The instrument will
emit an acoustic indication and the display will show the battery voltage level, the
charge percentage and how long the battery has been charging.
When a charging process is carried out within the allowed temperature margin with
the equipment switch off, it appears on the display the previous indications, in opposite
case is shown the message "wait...", and the process stops when activating the heat-
protection circuit. When charging is completed, the instrument is automatically
disconnected while you hear two acoustic indications and the display will show how
long the battery has been charging. In the case of charging process stops due to heat-
protection activation, this one will be started again automatically when the internal
temperature returns to the allowed margin for a normal battery charging.
Charging time depends on the state of the battery. If the battery is very flat,
charging will be some 70 minutes (40 minutes to achieve 60% total capacity). When the
battery is fully charged, the instrument automatically disconnects.
Due to the battery technology the reading of charge percetage will not be correct until
after about 5 minutes of beginning the charging process.
When starting the battery charging process and when using the instrument for a long
period of time, a heating of the instrument can be observed. This heating is normal in
the power margin that must be dissipated, according to the battery charge status and
the LNB consumption.
Page 10
[4] (see figure 7). Then connect the
Figure 1.- Battery charging.
IMPORTANT REMARK
IMPORTANT REMARK
05/2003
Tabla de contenido
loading

Tabla de contenido