17027034_0710 MAG 32 MAG 50 NAFTA.book Seite 6 Mittwoch, 28. Juli 2010 10:03 10
ENGLISH
ENG
"W". These cords are rated for outdoor use and
reduce the risk of electric shock.
4 Personal Safety
4.1 Stay alert, watch what you are doing and
use common sense when operating a power
tool. Do not use tool while tired or under the
influence of drugs, alcohol or medication. A
moment of inattention when operating power tools
may result in serious personal injury.
4.2 Dress properly. Do not wear loose clothing
or jewelry. Contain long hair. Keep your hair,
clothing and gloves away from moving parts.
Loose clothes, jewelry or long hair can be caught
in moving parts.
4.3 Avoid accidental starting. Be sure switch is
off before plugging in. Carrying tools with your
finger on the switch or plugging in tools that have
the switch on invites accidents.
4.4 Remove adjusting keys or wrenches before
turning the tool on. A wrench or a key that is left
attached to a rotating part of the tool may result in
personal injury.
4.5 Do not overreach. Keep proper footing and
balance at all times. Proper footing and balance
enable better control of the tool in unexpected
situations.
4.6 Use safety equipment. Always wear eye
protection. Dust mask, non-skid safety shoes,
hard hat or hearing protection must be used for
appropriate conditions.
5. Tool Use and Care
5.1 Use clamps or other practical way to secure
and support the workpiece to a stable platform.
Holding the work by hand or against your body is
unstable and may lead to loss of control.
5.2 Do not force tool. Use the correct tool for
your application. The correct tool will do the job
better and safer at the rate for which it is designed.
5.3 Do not use tool if switch does not turn it on
or off. Any tool that cannot be controlled with the
switch is dangerous and must be repaired.
5.4 Disconnect the plug from the power source
before making any adjustments, changing
accessories, or storing the tool. Such preventive
safety measures reduce the risk of starting the tool
accidentally.
5.5 Store idle tools out of reach of children and
other untrained persons. Tools are dangerous in
the hands of untrained users.
5.6 Maintain tools with care. Keep cutting tools
sharp and clean. Properly maintained tools with
sharp cutting edges are less likely to bind and are
easier to control.
5.7 Check for misalignment or binding of
moving parts, breakage of parts, and any other
condition that may affect the tool's operation. If
6
damaged, have the tool serviced before using.
Many accidents are caused by poorly maintained
tools.
5.8 Use only accessories that are
recommended by the manufacturer for your
model. Accessories that may be suitable for one
tool may become hazardous when used on
another tool.
6 Service
6.1 Tool service must be performed only by
qualified repair personnel. Service or
maintenance performed by unqualified personnel
could result in a risk of injury.
6.2 When servicing a tool, use only identical
replacement parts. Follow instructions in the
Maintenance section of this manual. Use of
unauthorized parts or failure to follow Maintenance
instructions may create a risk of electric shock or
injury.
3 Specific Safety Rules
Always use securing strap. Mounting can
release.
WARNING – Reading the operating
instructions will reduce the risk of injury.
For your own protection and for the
protection of your power tool pay atten-
tion to all parts of the text that are
marked with this symbol!
For work carried out on angled and vertical
surfaces and overhead, the magnetic drill
stand must be secured with the securing
strap supplied to prevent it from falling if the power
supply is interrupted.
When the magnet is switched off, or if the power
supply is interrupted, the magnet loses it holding
power. The machine executes a dangerous
swinging movement.
Always wear a hard hat when working overhead.
Always wear protective goggles, gloves, and suit-
able shoes when working.
Ensure there is no damage to the mains connec-
tion cables, switch and anti-kink device.
The magnet produces magnetic and electromag-
netic fields that can have a negative effect on
medical implants.
The surface for the electromagnet must be clean
and flat.
The magnet holding power depends on material
thickness and condition.
Paint, zinc and oxide layers reduce the magnet
holding power.