APPLICATIONS
○ Driving and removing of machine screws, wood screws,
tapping screws, etc.
○ Drilling of various metals
○ Drilling of various woods
SPECIFICATIONS
The specifi cations of this machine are listed in the Table on
page 150.
NOTE
Due to HITACHI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
Before
charging
While charging Lights (red)
Charging
complete
The pilot
lamp
Charging
lights or
impossible
blinks.
Overheat
standby
● Regarding the temperatures and charging time of the battery.
The temperatures and charging time will become as shown in Table 2
Battery
Charging voltage
Weight
Temperatures at which the battery can be
recharged
Charging time for battery capacity, approx.
(At 20oC)
1.3 Ah
1.5 Ah
2.0 Ah
2.5 Ah
3.0 Ah
4.0 Ah
5.0 Ah
Number of battery cells
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
Blinks (red)
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
Blinks (red)
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
Flickers (red)
seconds. (off for 0.1 seconds)
Lights (green)
Lights continuously
(UC18YRSL)
Blinks (red)
Lights for 1 second. Does not light for 0.5
(UC18YFSL)
seconds. (off for 0.5 seconds)
(UC18YGSL)
(UC18YKSL)
Charger
UC18YRSL
V
kg
min.
min.
min.
min.
min.
min.
min.
CHARGING
Before using the power tool, charge the battery as follows.
1. Connect the charger's power cord to the receptacle.
When connecting the plug of the charger to a receptacle,
the pilot lamp will blink in red (At 1- second intervals).
CAUTION
Do not use the electrical cord if damaged. Have it
repaired immediately.
2. Insert the battery into the charger. (Fig. 2)
Firmly insert the battery into the charger.
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously in
red.
When the battery becomes fully recharged, the pilot lamp
will blink in red. (At 1-second intervals) (See Table 1)
● Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or the
rechargeable battery.
Table 1
Table 2
UC18YFSL
14.4 V - 18 V
0.6
0.5
0oC – 50oC
20
20
22
22
30
30
35
35
45
45
60
60
75
75
5
Malfunction in the
battery or the charger
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
UC18YGSL
UC18YKSL
0.4
35
40
60
75
90
120
150
4 – 10
English
0.35
35
40
60
75
90
120
150