POS.
REFERENCE
7
INITIAL LOAD
8
STOVE STATE
TECHNICA
9
SETTING
10
SET FLAME
10.5
START UP
We remind you that the first ignition must be carried out by a specialized and authorixed technician who
will check that all is installed in compliance with current regulations and checks the efficiency.
• If inside the combustion chamber there are booklets, manuals, etc..., remove them.
• Check if the door is correctly closed.
• Check if the stove is correctly inserted in the electric socket.
• Before switching the stove on, assure you the burning pot is clean.
• To start the stove up, keep pressed P4 key for an instant till it will be shown "START" and "PREHEATI WAIT":
the preheating of the ingnition resistance starts. After 2 minutes about, it will be shown "PELLET LOAD,
FLAME WAIT", in this phase the auger loads the pellet and the heating of the resistance continues. When
the temperature is sufficiently high (after 7-10 minutes about), the ignition is considered as happened
and on the display shows "FIRE PRESENT".
• Completed the phase "FIRE PRESENT", the control unit enter the "WORK" phase showing the set calorific
power and ambient temperature. It is in this phase that P5 and P6 keys settle the stove power from 1 to
5. If the value of the ambient temperature exceeds the limit set on the keyboard on the temperature
setting, the calorific power will be carried at the minimum showing "WORK, MODULATI". When the
ambient temperature turns back below the set temperatur, the stove turns back to the set power.
10.6
STOVE ADJUSTMENT
The stove is adjusted according to the chimney flue and used pellets datas, as per technical characteristics
(see FEATURES page 88). If the datas do not correspond, the authorized technician can adjust the stove.
• If the pellet is small in size and with a greater calorific power, (for example: encrusted burning pot),
the pellet drop must be decreased from the menu "SET FLAME", press P3 "PELLET TYPE", press P3 again
"PELLET LOAD" and with P2 key decrease the pellet quantity from -1 (which is -2%) till -9 (which is -18%).
• If the chimney flue has a lower draught (for example: weak flame, sooty glass) the revolutions of the
geared motor must be increased from the menu "SET FLAME", press P5 "CHIMNEY TYPE", press P3 "FUME-
FAN CHIMNEY" and with P1 key increase the fume fan revolutions from +1 (which is +5%) till +9 (which is
+30%).
• If the chimney flue has a greater draught (for example: because of pellets fall on the burning pot)
decrease the fume fan revolutions from -1 to -9.
Pay attention if the value is positive or negative..
10.7
AIR REGULATOR
The stove is provided with a back air regulator and must have the following parameters (written also on the
back of the stove):
NICE - MIRIAM - CRISTAL - LEONORA - PRETTY - DIANA - KRISS - MARY
DESCRIPTION
When the stove has its first ignition, the auger is completely empty. If it should be
necessary do a precharge by pressing P3 key, then P1 key for starting up and P4 key
for stop.
It shows all parameters connected to the stove state: this is a menu for the Authorized
Techinician
Only for the Authorized Technician.
It enables to set the flame dipending on the draught of the chimney flue.
EN