will be displayed at the end of the welding process and
will be counted down to zero. This countdown can be ac-
knowledged and canceled at any time by the STOP/RESET
key. However, note that for that time the pipe fitting joint
which is still warm must not be subjected to an external
force. No cooling time is displayed if the fitting code does
not contain any such information.
5.10 Returning to the Start of Parameter Input
After welding is finished, disconnecting the welded fitting
from the unit or pressing the STOP/RESET key will reset the
unit back to the start of entering the welding parameters.
5.11 Using ViewWeld to Manage Logged Welding
Reports and Print Tags
The ViewWeld feature offers viewing an abstracted ver-
sion of the welding reports recorded during the welding
processes and printing it as a label tag to be affixed to the
joint on the optionally available tag printer. The ViewWeld
abstract shows the report number, the date and time of
the welding and the welding parameters along with an
evaluation of the quality of the joint/welding operation
(see Display 6), where the first displayed abstract is that
of the last performed welding operation.
To call the ViewWeld abstract of a welding report, press the
ñ key in the bar code input screen (see Display 2). Browsing
through the saved welding reports is then possible by press-
ing the ï or ð cursor keys. To print a tag of the welding
operation of which the abstract is currently displayed, the
label tag printer has to be connected to the welder. Then
press the START/SET key in the ViewWeld screen.
6
Additional Information in the Welding Report
Every welding report saved to system memory, which can
be downloaded as a PDF report file or in the DataWork
format, contains a number of welding and traceability data
that the operator can decide to enter or not to enter in
the set-up menu.
6.1 Entering Preformatted and User-defined
Traceability Data
All traceability data enabled in the configuration menu at
"Data Recording" (see Sect. 10) have to be entered before
the welding process. The welding unit prompts the user to
enter them either before or after entering the fitting bar
12
EN
HÜRNER HST 300 Print 315 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
0015
24.02.13 09:33
M/B
MON HST
0058s
025.0V
Welding OK
***
Recording
>Welder ID Code
Enter Job No.
Version September 2018
315
1.57Ω
Display 6
****
Display 7