Alarm Codes - voestalpine Böhler TERRA 180 TLH Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
8
Basic current
Permits adjustment of the basic current in pulsed and
fast pulse modes.
Parameter setting: Amperes (A) - Percentage (%).
Minimum 3A-1%, Maximum Imax-500%, Default 50%
9
Base current (%-A)
Permits adjustment of the base current in pulsed and
fast pulse modes.
Parameter setting: Amperes (A) - Percentage (%).
0=A, 1=%, Default %
10
Pulsed frequency
Allows activation of the pulse mode.
Allows regulation of the pulse frequency.
Allows better results to be obtained in the welding of
thin materials and better aesthetic quality of the bead.
Parameter setting: Hertz (Hz).
Minimum 0.5Hz, Maximum 20.0Hz, Default 4.0Hz
11
Pulsed duty cycle
Allows regulation of the duty cycle in pulse welding.
Allows the peak current to be maintained for a shorter
or longer time.
Parameter setting: percentage (%).
Minimum 20%, Maximum 80%, Default 50%
12
Fast Pulse frequency
Allows regulation of the pulse frequency.
Allows focusing action and better stability of the electric
arc to be obtained.
Parameter setting: KiloHertz (KHz) - KiloHertz (kHz).
Minimum20Hz, Maximum 2.5KHz, Default 100Hz
13
Slope-down
Allows you to set a gradual passage between the weld-
ing current and the final current.
Parameter set in seconds (s).
Minimum off, Maximum 10.0s, Default off
14
Final current
Permits adjustment of the final current.
Parameter setting: Amperes (A) - Percentage (%).
Minimum 3A-1%, Maximum Imax-500%, Default 50%
15
Final current (%-A)
Permits adjustment of the final current.
Parameter setting: Amperes (A) - Percentage (%).
0=A, 1=%, Default %
16
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Parameter set in seconds (s).
Minimum 0.0s, Maximum 25.0s, Default syn
17
Start current (HF start)
Parameter setting: Amperes (A).
Minimum 3A, Maximum 170A, Default 100A
18
TIG start (LIFT)
Allows selection of the required arc striking modes.
On=LIFT START, Off= HF START, Default HF START
19
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Allows the timing of the welding process.
Parameter setting: seconds (s).
Minimum off, Maximum 99.9s, Default off
20
Restart
Allows the activation of the restart function.
Allows the immediate extinguishing of the arc during
the down slope or the restarting of the welding cycle.
0=Off, 1=On, Default On
28
21
(TIG DC) Easy joining
Allows striking of the arc in pulsed current and timing of
the function before the automatic reinstatement of the
pre-set welding conditions.
Allows greater speed and accuracy during tack welding
operations on the parts.
Parameter setting: seconds (s).
Minimum 0.1s, Maximum 25.0s, Default off
40
Measurements
Permits selection of the type of measurement to be
shown on the display 8.
0 Real current
1 Real voltage
2 No measurement
Default 0
42
(U/D) Adjustment step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum IMAX, Default 1
43
CH1 MIN External parameter
Allows the management of external parameter 1 (mini-
mum value).
44
CH1 MAX External parameter
Allows the management of external parameter 1 (maxi-
mum value).
48
Buzzer volume
Adjustment of the buzzer volume.
Minimum Off, Maximum 10, Default 5
49
Contrast
Adjustment of the LCD display contrast.
Minimum Off, Maximum 15, Default 12
99
Reset
Allows you to re-set all the parameters to the default
values and restore the whole system to the conditions
predefined.

3.4 Alarm codes

E01, E03
Temperature alarm
It is advisable not to switch off the equipment while
the alarm is on; the internal fan will thus keep oper-
ating and will help to cool the overheated parts.
E11
System configuration alarm
E20
Memory fault alarm
E21
Data loss alarm
Tabla de contenido

Solución de problemas

loading

Tabla de contenido