A 50 amp range cord is not recommended but if used, it should be marked for
use with nominal 1⅜" diameter connection openings. Care should be taken to
center the cable and strain relief within the knockout hole to keep the edge from
damaging the cable.
Because range terminals are not accessible after range is in position, flexible
service conduit or cord must be used.
NOTE
If conduit is being used, go to Step 5 on pages 23–24.
ALL NEW BRANCH-CIRCUIT CONSTRUCTIONS, MOBILE HOMES,
RECREATIONAL VEHICLES AND INSTALLATIONS WHERE LOCAL
CODES DO NOT ALLOW GROUNDING THROUGH NEUTRAL, REQUIRE A
4-CONDUCTOR UL-LISTED RANGE CORD.
Step 3. Accessing the power cord connection
Remove the rear access cover and loosen the screw with a screwdriver. The
terminal block will then be accessible.
Terminal block
Install_NY9900R_CHEF_NY36R9966PS_AA_DG68-01106B-01_EN+MES+CFR.indb 21
Specified power-supply-cord kit rating
volts 3-wire
8750 - 16500 7801 - 12500
Step 4. Installing the power cord
For power cord installations, hook the strain relief over the power cord hole (1⅜")
located below the rear of the drawer body. Insert the power cord through the
strain relief and tighten the device.
Access cover
Range rating, watts
Specified rating
of power-supply-
120/240
120/208
cord kit, amperes
volts 3-wire
40 or 50 A
You must install the power cord with a strain relief.
Attach the strain relief to the 1⅜" opening in conduit connection plate.
Diameter (inches) of range
connection opening
Power cord
Conduit
1⅜"
1⅛"
English 21
2019-03-14
3:55:57