Replacing The Ac Fuse; Replacing The Dc Fuse; Replacing The Dc Plug Fuse; Replacing The Light Pcb - Dometic CFX3 35 Instrucciones De Uso

Nevera por compresor
Ocultar thumbs Ver también para CFX3 35:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CFX3
7.22

Replacing the AC fuse

D
DANGER! Electrocution hazard
Disconnect the power supply and the connection cable before you
replace the device fuse.
➤ Disconnect the power supply to the device.
➤ Pull out the connection cable.
➤ Pry out the fuse insert (fig. 4 4, page 4) with a screwdriver.
➤ Replace the defective glass fuse with a new one of the same type and rating
(Fast Acting, 4 A, 250 V).
➤ Press the fuse insert back into the housing.
➤ Reconnect the power supply to the device.
7.23

Replacing the DC fuse

➤ Pry out the fuse cover (fig. 4 3, page 4) with a screwdriver.
➤ Reverse the fuse cover and use hook to remove the defective blade fuse.
➤ Push in a new fuse of the same type and rating.
– CFX3 35, CFX3 45, CFX3 55IM, CFX3 75DZ: 10 A
– CFX3 95DZ, CFX3 100: 15 A
➤ Re-fit the fuse cover.
7.24

Replacing the DC plug fuse

➤ Replace the defective fuse with a new fuse of the same type and rating.
– CFX3 35, CFX3 45, CFX3 55IM, CFX3 75DZ: 10 A
– CFX3 95DZ, CFX3 100: 15 A
➤ Proceed as shown (fig. p, page 15).
7.25

Replacing the light PCB

A
NOTICE! Damage hazard
The lamp can only be replaced by the manufacturer, service agent or
similarly qualified person to avoid hazard.