Connecting the air extractor (only for
ducted operation)
Note: If an aluminum pipe is used, smooth the
connection area beforehand.
Attach exhaust air pipe and seal.
1.
Check whether the back-pressure flap works.
2.
Mounting the recirculation model (only for
circulating-air mode)
Use 2 screws to screw the housing for the
1.
recirculation module to the ceiling bracket.
Measure the distance (x) between the lower edge of
2.
the housing for the recirculation module and the lower
edge of the back-pressure flap.
Shorten the exhaust air pipe to the length measured.
3.
Push the exhaust air pipe onto the bottom of the
4.
recirculation module.
Position the recirculation module with exhaust air pipe
5.
over the air extraction duct of the extractor hood.
Use aluminum tape (NOT insulating tape) to seal the
6.
fastening of the exhaust air pipe on the recirculation
module and on the air extraction duct of the extractor
hood.
12
Connect Electrical Supply
WARNING
9
RISK OF ELECTRIC SHOCK
Before wiring the appliance, interrupt the main
electrical circuit at the electrical control cabinet. A
circuit with 120 VAC, 15 or 20 Ampere is required.
Grounding notes: this appliance is equipped with a
distributor box with 3 cables. Use the green-yellow
cable for grounding the appliance. Connect the
green-yellow cable to the grounding cable on the
house connection to prevent electric sthock. Do not
under any circumstances damage or remove the
green-yellow cable. Non-adherence can cause
deadly injuries or electric shock.
Remove the left cable passage and the cover of the
1.
motor controller. Fasten the connecting piece for the
installation pipe (listed in cULUS) to the cable
passage.
A
Cable passage
B
Cover of the motor controller
Connect 1/2" (12.7 mm) installation pipe to motor
2.
controller.
A
Installation pipe
B
Power connection
C
Cable connector listed in UL