Mounting the extractor hood on the wall
, WARNING
RISK OF INJURY
The appliance is heavy. To move the appliance,
2 people are required. Use only suitable tools and
equipment.
1. Initially remove the protective foil from the back of the
appliance and, following installation, remove foil
completely.
2. Mark the upper holes on the wall.
Note: Ensure that the holes are horizontal and aligned
centered on the center line.
3. Drill the upper holes. Adhere to a distance of 1/4"
(6 mm) between the wall and screw head.
4. Remove grease filters.
5. Hang the extractor hood on the upper screws on the
wall.
6. Mark holes for the lower holes.
7. Remove the extractor hood from the wall.
8. Drill the lower holes.
9. Hang the extractor hood on the upper screws on the
wall.
10. Tighten the upper and lower screws by hand.
Mounting the back-pressure flap
Using 4 screws (4x8 mm), attach the back-pressure flap to
the extractor hood.
Connecting the air extractor (only for
ducted operation)
Note: If an aluminum pipe is used, smooth the connection
area beforehand.
1. Attach exhaust air pipe and seal.
2. Check whether the back-pressure flap works.
Mounting the recirculation model (only
for circulating-air mode)
1. Use 4 screws (4x8 mm) to screw the housing to the
angle bracket.
A
Screws
B
Recirculation Module
C
Angle bracket
2. Measure the distance (x) between the bottom edge of
the housing for the recirculation module and the bottom
edge of the back-pressure flap.
A
Recirculation Module
B
Clamps
C
Flue Duct
D
Exhaust Air Duct
3. Shorten the exhaust air pipe to the length measured.
4. Remove the recirculation module.
5. Push the exhaust air pipe onto the bottom side of the
recirculation module.
6. Position the recirculation module with exhaust air pipe
over the air extraction duct of the extractor hood.
7. Use 4 screws to fasten the recirculation module to the
angle bracket.
8. Secure connections with clamps.
13