seCTIoN 4
4.5
sWITCh AND PILoT ARC PLUGs
WARNING
WHITE SWITCH LEADS ()
FROM TORCH SWITCH
SWITCH PLUG
P/N 066
STRIP INSULATION 1/4" (6.4 mm)
A. sWITCh PLUG
CHROME PLATED TERMINAL
BRASS TERMINAL
figure 4-4. switch and Pilot Arc Plug Removal/Replacement
Do NoT INTeRChANGe The ToRCh sWITCh PLUG AND The PILoT
ARC PLUG. If IT BeCoMes NeCessARY To ReMoVe These PLUGs,
MAKe sURe The sWITCh PLUG (P/N 2062336) Is ATTACheD To The
TWo WhITe sWITCh LeADs AND The PILoT ARC PLUG (P/N 21427) Is
ATTACheD To The BLACK LeAD WITh The BLUe JUMPeR WIRe.
INTeRChANGING These PLUGs MAY CReATe AN UNsAfe CoNDITIoN
ThAT CoULD CAUse eLeCTRIC shoCK AND BURNs.
STRAIN RELIEF
TUBING - P/N 186
BLUE JUMPER
PILOT ARC PLUG
P/N 147
B. PILoT ARC LeAD AND PLUG
(oN ToRCh AsseMBLY 21620)
CHROME PLATED TERMINAL
BRASS TERMINAL
*PILOT ARC PLUG
P/N 147
*TORCH ASSEMBLY 1661 USES A RING CONNECTOR IN PLACE OF THIS
PLUG (REFER TO FIGURE 5-1)
BLACK PILOT ARC LEAD
(ATTACH TO CHROME PLATED TERMINAL)
STRAIN RELIEF TUBING
P/N 16
6
MAINTeNANCe
BLACK PILOT ARC LEAD
STRAIN RELIEF
TUBING - 16
BLUE JUMPER
(SEE BELOW)
Do NoT sTRIP INsULATIoN fRoM
These ThRee WIRes