10. Specifications

Model
Capacity (VA)
Capacity (Watts)
INPUT
Nominal Voltage
Voltage Range
Voltage Comeback
Nominal Frequency
Frequency Range
Phase
Power Factor (100% Load)
Harmonic Distortion (THDi; 100% Load)
OUTPUT
Phase
Nominal Voltage
AC Voltage Regulation
(Double-Conversion Mode)
AC Voltage Regulation
(Converter Mode or Battery Mode)
Power Factor
AC Voltage Regulation (ECO Mode)
Frequency
Frequency Regulation
(Converter Mode or Battery Mode)
Frequency Range (Battery Mode)
Overload (AC Mode)
Overload (Battery Mode)
Current Crest Ratio
Harmonic Distortion (100% Load)
Transfer Time (Line ‹—› Battery)
Transfer Time (Inverter ‹—› Bypass)
Transfer Time (Inverter ‹—› ECO)
BYPASS INPUT
Nominal Voltage
Phase
Voltage Range
Nominal Frequency
Frequency Range
Overload (Bypass Mode)
EFFICIENCY
AC Line Mode
ECO Mode
Battery Mode
PARALLEL
Parallel for Capacity
Parallel for Redundancy
EXTERNAL BATTERIES
(S3M100KX/KXD*, S3M120KX/KXD*, S3M160KX/KXD* and S3M200KX/KXD* require external batteries to operate.)
Type
DC Nominal Acceptance Voltage
Quantity
Maximum Charging Current
*KXD models are dual-AC input capable. **The UPS output Neutral must be connected to the Load Neutral at all times.
S3M100KX/KXD*
S3M120KX/KXD*
100 kVA
90 kW
Ph-Ph 380V/400V/415V (Ph-N 220V/230V/240V)
Ph-Ph 208-478V at < 50% Load; Ph-Ph 208-478V to 305-478V at 50% to 80% Load
(Voltage Range Varies with Load); > 80% Load: Ph-Ph 305-478V
Low-Loss Voltage +10V; High-Loss Voltage -10V
3-Phase with Neutral (3-Phase, Neutral + Ground)
3-Phase with Neutral (3-Phase, Neutral** + Ground)
Ph-Ph 380V/400V/415V (Ph-N 220V/230V/240V)
Selectable ± 1 Hz, ± 2 Hz, ± 4 Hz of Input (Default: ± 4 Hz)
50 Hz ± 0,1 Hz or 60 Hz ± 0,1 Hz
Up to 110% = 1 hr; Up to 125% = 10 min;
Up to 150% = 1 min; > 150% = 200 ms
Up to 110% = 1 hr; Up to 125% = 10 min;
Up to 150% = 1 min; > 150% = 200 ms
≤ 2% THD (Linear Load); ≤ 4% THD (Non-Linear Load)
Synchronous = 0 ms; Asynchronous < 1 cycle
3-Phase with Neutral (3-Phase, Neutral + Ground)
Upper Limit: +10%, +15% or +20% (Default: +15%)
Lower Limit: -10%, -20% or -30% (Default: -20%)
Selectable: ± 1 Hz, ± 2 Hz, ± 4 Hz (Default: ± 4 Hz)
105-110% = 1 hr; 111-125% = 10 min;
126-150% = 1 min; > 150% = 200 ms
94% at 100% Resistive Load; 93,5% at 50% Resistive Load
98% at 100% Resistive Load; 97% at 50% Resistive Load
93% at 100% Resistive Load; 92,5% at 50% Resistive Load
Requires external
N+1 bypass panel
Adjustable up to 24A
Adjustable up to 32A
± 1%
67
S3M160KX/KXD*
120 kVA
160 kVA
108 kW
144 kW
50/60 Hz (Auto-Selectable)
40-70 Hz
> 0,99
< 3%
±1% (Balanced Load)
±1%
0,9
± 15V of Nominal
± 0,1 Hz
3:1 Maximum
0 ms
< 20 ms
Ph-Ph 380V/400V/415V
50/60 Hz (Auto-Selectable)
Up to 2 Units
Up to 2 units
12V Non-Spillable VRLA AGM/GEL
± 240 VDC
40N (N ≥ 1 x Strings of 20 + 20)
Adjustable up to 40A
± 1%
± 1%
S3M200KX/KXD*
200 kVA
180 kW
Adjustable up to 48A
± 1%