Technical Data Romax 3000 - Rothenberger ROMAX 3000 Instrucciones De Uso

Ocultar thumbs Ver también para ROMAX 3000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
RISK OF FIRE! Never charge batteries near acids and highly flammable mate-
rials.
Battery fluid may leak from damaged removable batteries under conditions of extreme load or
extreme temperatures. Any areas that have come into contact with battery fluid should be
washed immediately with soap and water. If battery fluid comes into contact with the eyes rinse
them thoroughly for at least 10 minutes and consult a doctor immediately.
Do not store batteries with metal objects (danger of short circuit).
Check before each use: Carry out a visual inspection each time before using the battery
charger. Never charge a damaged battery pack. Replace by a new one.
The power supply (plug) / charging cable should be inspected regularly for signs of damage and
ageing (brittleness) and should only be used in perfect condition.
Never break open battery packs and chargers and store only in dry rooms. Keep dry at all times.
Storage:
The battery should be disconnected from the battery charger, so that the fully charged battery
does not discharged in the charger.
Only store the charger unplugged and only in temperature between 0-30°C/32-86°F.
Do not store the charger in direct sunlight!!
Transport:
The contained lithium-ion batteries are subject to the Dangerous Goods Legislation require-
ments. The user can transport the batteries by road without further requirements. When being
transported by third parties (e.g.: air transport or forwarding agency), special requirements on
packaging and labelling must be observed. For preparation of the item being shipped, consulting
an expert for hazardous material is required.
Dispatch batteries only when the housing is undamaged. Tape or mask off open contacts and
pack up the battery in such a manner that it cannot move around in the packaging. Please also
observe specific national regulations.
2

Technical data ROMAX 3000

Battery voltage .....................................................................
Battery capacity. ..................................................................
Rated power consumption ...................................................
Motor speed. ........................................................................
Maximum piston force ..........................................................
Pressing time (according to nominal size) ............................
Dimensions (L x W x H) .......................................................
Weight (without battery) .......................................................
Working range. ....................................................................
Application temperature range .............................................
Operating mode ...................................................................
Typical acceleration in hand-arm area .................................
Sound pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear ear protection!
Measurements found in compliance with EN 60745-1.
) ...................................................
pA
) ......................................................
WA
ENGLISH
18 V
3,0 Ah
540 W
22000 1/min
32kN
ca. 5 s
445 x 125 x 79 mm
ca. 2,9 kg
Ø 12 – 108 mm (system- dependent)
-10 – 60°C / 14 – 140°F
S3
≤ 2,5 m/s2
71 dB (A) ¦ K
3 dB (A)
pA
82 dB (A) ¦ K
3 dB (A)
WA
15
Tabla de contenido