Roger CTRL Instrucciones Y Advertencias Para El Instalador página 86

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 168
IMMEDIATE REVERSE. The barrier reverses immediately if the photocell is activated during closing manoeuvre.
TEMPORARY STOP. The barrier stops and remains stationary as long as the photocell is obstructed. The
barrier resumes closing when the photocell is cleared.
DELAYED REVERSE. The barrier stops if the photocell is obstructed. The barrier opens when the photocell
is cleared.
Photocell (FT) mode with barrier closed
N.B.: this parameter is not visible if the value of parameter
If the photocell is obstructed, the barrier cannot open.
The barrier opens when an open command is received, even if the photocell is obstructed.
The photocell sends the barrier open command when obstructed.
Enable close command 6 s after activation of photocell (FT)
N.B.: This parameter is not visible if
Disabled.
Enabled. When the photocell barrier FT is crossed, a close command is sent 6 seconds later.
Motor stop distance setting
The motor brake function is activated each time a stop is requested by a user command or by activation
of the photocells.
Set a value that will prevent collision with objects or persons due to the inertia of the boom.
01= rapid braking/smaller stopping distance ...
10= gentle braking (soft-stop)/greater stopping distance (NOTE
N.B.: Available values may be limited by the setting for parameter
Installation position of barrier relative to gateway (seen from interior side)
For installations with two opposed barriers, this setting must be made for the MASTER barrier. The SLAVE
barrier recognises its position automatically.
N.B.: every time the installation position is changed by altering parameter
position data request message
Barrier installed on the left, viewed from the inspection cover side. With passage opening on the right.
Barrier installed on the right, viewed from the inspection cover side. With passage opening on the left.
Sensing edge NOT INSTALLED.
NC contact (normally closed). The barrier reverses only when closing.
Contact with 8k2 resistor. The barrier reverses only when closing.
STEP MODE.
PARTIAL OPENING.
OPENING.
CLOSING.
STOP.
(1)
pressing CHB on the remote control. Press CHB to activate partial opening.
86
or
. Press the PROG key until
.
(1)
.
(1)
.
(1)
e
=
,
or
is set, and if value of parameter
.
appears on the display, then repeat
.
(1)
or if
=
,
,
or
=
,
or
.
, the display shows a
.
-
Tabla de contenido
loading

Tabla de contenido