Electrical Connections - Roger CTRL Instrucciones Y Advertencias Para El Instalador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 168
6.2

Electrical connections

A switch or an omnipolar cut-off switch with a contact opening of at least 3 mm must be
installed on the mains power line; put the cut-off switch in OFF position and disconnect any
buffer batteries before performing any cleaning or maintenance operations.
Ensure that an adequate residual current circuit breaker with a 0.03 A threshold and a suitable
overcurrent cut-out are installed upstream the electrical installation in accordance with best
practices and in compliance with applicable legislation.
For power supply, use a H07RN-F 3G1.5 type electric cable and connect it to the terminals L
(brown), N (blue),
Strip the insulation from the ends of the power cable wires which will be connected to the
Measure the voltage on the primary mains power connection with a tester.
TRANSFORMER
For the Brushless automation system to function correctly, the mains
- 230Vac ±10% for the CTRL control unit.
220÷230
- 115Vac ±10% for the CTRL/115 control unit.
A
V
N
L
V
A
+
-COM
Connections to the electrical distribution network and to any other low-voltage conductors
in the external section to the electrical panel must be on an independent path and
separate from the connections to the command and safety devices (SELV = Safety Extra Low
Voltage).
Make sure that the mains power conductors and the accessory wires (24 V) are separated.
The cables must be double insulated, strip them near the relevant connection terminals and
lock them with clamps [B] (not supplied).
DESCRIPTION
Connection to mains power, 230 Vac ±10% (115 Vac ±10% 60 Hz).
- 230 Vac ± 10% for CTRL control panel.
- 115 Vac ± 10% for CTRL/115 control panel.
Fuse 5x20 T1A.
Fuse 5x20 T2A (mains power 115 Vac).
N
L
Secondary transformer input for 26 V AC motor power (SEC1) and for 19 V power to logical
control and peripheral devices (SEC2).
N.B.
3
4
5 6
X-Y-Z
Connection to ROGER brushless motor.
N.B.
Warning! If the motor wires become disconnected from the terminal board, after reconnect-
Y
7
8
9
M
ing correctly, the travel must be acquired again as described in chapter 11.
X
Z
Connection to the battery BI/BAT/KIT
BATTERY (+)
BATTERY (-)
(yellow/green), located inside the control panel box.
See instructions for B71/BCHP or BI/BCHP for further information.
69