Reset system (only available for master thermostat Blueface). Resets the system and returns to factory settings. To
reconfigure the thermostats, please check Initial configuration).

Zone Parameters

·
Linked zones. It displays and allows you to select the control outputs associated with the thermostat.
·
Thermostat type. Use this parameter to define the thermostat as Main or Zone.
*Note: It cannot be configured as Master if there is already another Master thermostat.
·
Mode menu. The thermostats can be set in Basic or Advanced mode. They are set in advanced mode by default. These
are the parameters you can control in basic mode:
-
On/Off.
-
Set-point temperature.
-
Local ventilation.
-
User settings.
If you need to reset the thermostat to advanced mode, access the advanced configuration menu and then activate the
advanced use mode.
·
Offset. Allows you to correct ambient temperature that is measured in the various areas or in all of them, due to
deviations by sources of heat/cold nearby, with a correction factor between - 2,5˚C and 2,5˚C in steps of 0,5˚C. It is in
0˚C by default.
·
User Mode Setpoint. This option is used to configure the set point temperature of each user mode for each zone.
Comfort. Heating mode: 15 to 30˚C, by default 20˚C. Cooling mode: 18 to 30˚C, by default 24˚C.
o
Eco. Heating mode: 15 to 30˚C, by default 19˚C. Cooling mode: 18 to 30˚C, by default 29˚C.
o
Unoccupied. Heating mode: 15 to 22˚C, by default 17.5˚C. Cooling mode: 24 to 30˚C, by default 27˚C.
o
Vacation. Heating mode: 10 to 16˚C, by default 10˚C. Cooling mode: 29 to 35.5˚C, by default 35˚C.
o
·
Weight. This option is used to set the weight of each zone for purposes of determining system operation. The weight
of the zone will be used for calculating the mode (auto-change over) or for calculating heat demands when using
auxiliary heat. Options: Auto or Manual.
Auto (by default). The weight of each zone is automatically assigned based on the number of zones.
o
Manual. Enables to manually define the weight of the zone. Values: 0 to 100.
o
·
Reset thermostat. Resets the thermostat returning to Setup menu (see section Initial configuration).