Installation • Instalación
Installation • Instalação
14
All manuals and user guides at all-guides.com
english
Connecting the feed line:
• The connecting adaptor and the
pressure relief chamber (PRC) can
be turned in relation to the inflow
direction:
- Remove the screws (notice O-ring
and washers of connecting adaptor).
- Pla ce con nect ing ad apt or /
pre ssur e re lief ch ambe r in to
position.
- Replace the screws and tighten.
• Connect the inlet hose (inside dia. =
0.5") to any adaptor inlet point by
means of a hose clamp (use the
hose connectors supplied with the
unit).
• Check that the unused inlet points
are tightly plugged!
• In the case of a collecting line
use the installation set (acces-
sories):
- Screw hose connector G1 from
installation set into connecting
adaptor.
• No
condensat e, until the
ÖWAMAT has been put into
operation!
Connection set
ÖWAMAT 6
XZ KT04 AS1
ÖWAMAT 8
XZ KT04 AS1
3. Wastewater drain
• Must be lower than the water outlet
of the ÖWAMAT
• Install a siphon against odours
Connecting the wastewater hose:
• Use the hose supplied and attach it
to the ÖWAMAT water outlet.
ÖWAMAT 6, 8