en
|
Technical data
16
Technical data
16.1
General data
Housing material
Stainless steel
Housing protection class
IP 66/IP 67
Weight of gas detector (without
approx. 3.2 kg (7.0 lb)
battery pack)
Weight of battery pack
approx. 0.6 kg (1.3 lb)
For information about the dimensions, see appendix "Dimensions".
16.2
Power supply
Wired power supply
Power supply unit
The power supply must comply with the
National Electric Code (NEC) Class 2 or
Protection Class II specification.
Cable type
2-core cable
Conductor
24 to 12 AWG / 0.2 to 2.5 mm²
Thread of cable entry
M 25 x 1.5
Operational voltage
14...30 V
Inrush current
0.5 A for 3 ms at 30 V
resistance;
0.7 A for 3 ms at 30 V
resistance
Power consumption
0.5 W
Operational parameters for
U
power supply with safety barrier
52
, 10 Ω conductor
, 1 Ω conductor
= 30 V, P
= 1.2 W, C
= 20 nF, L
= 0 mH
i
i
i
i
Instructions for use
Battery operation
Operating time of the battery
pack
16.3
Ambient conditions
Operation
1)
Temperature
1)
Pressure
Humidity
Storage
1)
Temperature
1)
Pressure
Humidity
1)
For the limitations of the maximum specification, refer to the corresponding sensor data sheet.
17
Accessories and spare parts
Description
Premium antenna (2 dBi)
Standard antenna (2 dBi)
®
|
Dräger Polytron
6100 EC WL, Dräger Polytron
Up to 24 months depending on:
–
Operational parameters (e.g., sensor
™
type, ISA100 Wireless
publication rate,
use of the repeater function, active
LEDs)
–
Usage behavior (e.g., Bluetooth
face)
–
Ambient conditions (e.g., temperature)
-40 to +65 °C (-40 to +149 °F)
700 to 1300 hPa (20.7 to 38.4 in. Hg)
0 to 100 % r.h., non-condensing
-40 to +65 °C (-40 to +149 °F)
900 to 1100 hPa (26.5 to 32.4 in. Hg)
0 to 100 % r.h., non-condensing
Order number
83 27 813
37 02 169
®
Repeater ISA
®
inter-