Operation
4.1
LED display
Symbol
LED display
Meaning
Green LED
Gas detector is switched on
flashes once
Yellow LED
Alerts (e.g., low battery or sensor warm-up
flashes once
phase active) or maintenance mode
Yellow LED lights
Error
up continuously
Red LED just
A1 alarm (pre-alarm)
flashes rapidly
Red LED rapidly
A2 alarm (main alarm)
flashes twice
Blue LED flashes
Bluetooth
once
Blue LED lights up
Bluetooth
continuously
mobile device
Yellow and blue
Confirmation, internal battery counter reset
LEDs light up
When the LED display is active, the energy consumption increases.
36
®
active
®
active, connected to Windows
Instructions for use
4.2
Communication interfaces
®
4.2.1
Bluetooth
interface
After the start sequence, the Bluetooth
activated.
If no connection is established, the gas detector disables the interface after 10
minutes (factory setting).
If the connection is to be secured with a pairing PIN, an additional pairing can
be carried out and an individual pairing PIN assigned. The factory setting is the
connection without PIN.
For safety-related applications, an individual pairing PIN must be assigned.
4.2.2
Activating the Bluetooth
®
● Activate the Bluetooth
interface with a magnetic pen or via the
™
ISA100 Wireless
network:
● Magnetic pen: Tap the marking (Fig. A 12).
™
● ISA100 Wireless
: Activate using PolySoft.
✓ The blue LED flashes.
4.2.3
Establish Bluetooth
Prerequisite:
®
–
Bluetooth
interface on the device and on the Windows terminal device is
activated.
● Connect via PolySoft.
Entering a PIN is not necessary.
✓ After successful connection, the blue LED lights up continuously.
Gas detector and Windowsterminal device with PolySoft are connected.
4.2.4
Carry out Bluetooth
Prerequisite:
®
–
Bluetooth
interface on the device and on the Windows terminal device is
activated.
®
–
Bluetooth
pairing is activated (with PolySoft).
®
|
Dräger Polytron
6100 EC WL, Dräger Polytron
®
interface of the gas detector is
®
interface
®
connection without pairing
®
pairing and connect
®
Repeater ISA