Ugolini Mini GEL Manual De Servicio página 16

Ocultar thumbs Ver también para Mini GEL:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Next comes the temperature entry test which will indicate the current temperature detected by the probe on the display. To exit Test
Mode, switch off the machine.
4 PRODUCTION TEST MODE
This mode is activated by switching on the machine with the H key held down. In this mode, pressing the A key in succession will
allow individual outlets to be switched on and off. The outlet codes will be indicated on the display. Once the activation of the outlets
is complete, the temperature detected will be displayed. To exit the test, switch off the machine.
5 PROTECTION AGAINST EXCESSIVE DENSITY
In the case of excessive product density, in order to avoid damage to the dispenser, both the freezer and the mixer will be stopped
for three minutes and one of the following messages will appear on the display: "AL03", "AL06" or "AL08". After three minutes, both
mixing and freezing will be reactivated and the previous density setting will be decreased by one level.
To reset the alarm message and return to the fixed display, hold down the B key for three seconds.
6 ALARMS
The table below summarises the machine's alarm codes:
COV
Cover opened
AL02
Product temperature alarm
AL03
Excessive motor absorption
AL04
Temperature probe damaged
AL05
Circuit board transmission error
AL06
Unplanned motor stop
AL07
24V power supply missing
AL08
Excess current, hardware protection intervention
If one of these alarm codes appears on the display, please refer to Appendix 1: Possible Problems and their Solutions.
7 FIRMWARE VERSIONS CHRONOLOGY
Control panel and display circuit board
022
First production version
023
Error correction. With the control panel locked, it was possible to modify the machine operation mode
025
- Fixed delay ignition light (B) of the general power.
- Added parameter PA08 to manage temperature in ° C or ° F.
- In normal operation alarms AL03, AL06 and AL08 are no longer displayed on the display. During the waiting time in
case of engine block to display bar appears "----". Super Service Mode Service or all the alarms are displayed on the
display.
- Removed PA23 number of motor poles.
- Changed default values of the parameters.
- Fixed bug that prevented output drive in test functions.
Main circuit board
017
First production version
018
- Introduced acceleration ramp startup brushless motor.
- Improved responsiveness brushless controller.
- Added 5-second delay before the decrease in density at the restart after motor break due to blockage.