Ocultar thumbs Ver también para Mini GEL:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PA07
Lock Keypad.
PA08
Scale representation of temperature.
PA09
Firmware version display circuit board.
PA10
Firmware version power circuit board.
2 SUPER SERVICE MODE – ADJUSTING THE MANUFACTORY PARAMETERS
By switching on the dispenser using the master switch and holding down keys A and H simultaneously, the machine can be started
up in Super Service Mode and make adjusting the manufactory parameters. The dispenser will function normally, but it will be pos-
sible to modify the production parameters and any modifications carried out will be stored in the memory for the next time the dispen-
ser is switched on in normal mode.
For information on how to adjust the production parameters, please refer to the instructions for the operation parameters.
Incorrect adjustment of the Production Parameters may compromise the opera-
tion of the machine.
LIST OF PRODUCTION PARAMETERS
NAME
DESCRIPTION
PA11
Ice Cream Production Mode Density
PA12
Ice Cream Production Mode Density Hysteresis
PA13
Ice Cream Production Mode Temperature Hysteresis
PA14
Compressor lockout time OFF
PA15
Electrovalve lockout time OFF
PA16
Time for which the density must remain above the reference value
PA17
Conservation Mode Temperature Hysteresis
PA18
Maximum motor absorption
PA19
Motor cooling time
PA20
Motor protection intervention delay
PA21
Product conservation alarm temperature
PA22
Tap sensor entry activation
PA23
Temperature probe offset
PA24
Number of motor poles
PA25
Motor control proportional P constant
PA26
Motor control integral I constant
PA27
Motor control derivative D constant

3 TEST MODE

When the machine is started up in test mode, it is possible to check the function of individual components by activating them one by
one. The Test Mode is activated by switching on the machine whilst holding down the E key. The display test will be carried out first.
When the A key is pressed, the machine moves on to the control panel test, during which each key should be pressed and the cor-
responding code should appear on the display. Pressing the A and E keys simultaneously then moves the machine on to the outlet
tests, during which the C or D keys can be used to select an individual outlet and the H key can be used to activate and deactivate
the selected outlet. The message "out" followed by the number of the outlet selected will appear on the display, according to the
following table:
out 1
compressor
out 2
geared motor
out 3
defrost fan
out 4
lights circuit board
out 5
valve
IMPORTANT
15
ON...OFF
C...F
Visualisation only
Visualisation only
ADJUSTMENT INTERVAL
1...10
0...1
0...5 °C
0...600 s
0...600 s
0...60 s
0...5 °C
0...100 W
0...600 s
0...60 s
0...10 °C
ON...OFF
?
0...1000
0...1000
0...1000
YES...NO
OFF
C
DEFAULT VALUE
5
0,25
0,5
120
60
1
0,5
90
90
30
4
OFF
0
300
4
0
NO
Tabla de contenido
loading

Tabla de contenido