Troubleshooting

The following symptoms do not indicate malfunction.
Symptom
Mist emerges from indoor unit.
Water fl owing sound during operation.
The room has a peculiar odour.
Indoor fan stops occasionally during automatic fan
speed setting.
Airfl ow continues even after operation has stopped. • Extraction of remaining heat from the indoor unit
Operation is delayed a few minutes after restarting. • The delay is a protection to the unit's compressor.
Outdoor unit emits water/steam.
TIMER indicator is always on.
POWER indicator blinks during HEAT mode with no
warm air supply (and louver is closed).
Indoor fan stops occasionally during heating
operation.
POWER indicator blinks before the unit is switched
on.
Cracking sound during operation.
Splashing sound during operation.
Dusts accumulated on the wall.
During COOL/DRY mode, the indoor unit stops and
POWER indicator blinks.
Discoloration of some plastic parts.
Check the following before calling for servicing.
Symptom
Operation in HEAT/COOL mode is not working
effi ciently.
Noisy during operation.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.
The unit does not receive the signal from the
remote control.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND
UNPLUG then please consult authorised
dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the
remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning
properly.
16
All manuals and user guides at all-guides.com
• Condensation effect due to cooling process.
• Refrigerant fl ow inside the unit.
• This may be due to damp smell emitted by the wall, carpet,
furniture or clothing.
• This helps to remove the surrounding odour.
(maximum 30 seconds).
• Condensation or evaporation occurs on pipes.
• The timer setting repeats daily once set.
• The unit is in defrost mode (and AIR SWING is set to AUTO).
• To avoid unintended cooling effect.
• This is a preliminary step in preparation for the operation
when the ON timer has been set.
• Changes of temperature caused the expansion/contraction
of the unit.
• Generating the nanoe on the unit.
• Due to air circulation or static electricity generated by the
air conditioner. Some types of wall paper may collect dusts
easily (recommended to clean the area around the air
conditioner frequently).
• The system has locked to operate in HEAT model only.
• Discoloration is subject to material types used in plastic parts,
accelerated when exposed to heat, sun light, UV light, or
environmental factor.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
• Check if the unit has been installed at an incline.
• Close the front panel properly.
• Insert the batteries correctly.
• Replace weak batteries.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
• Make sure the receiver is not obstructed.
• Certain fl uorescent lights may interfere with signal transmitter.
Please consult authorised dealer.
The unit stops and the TIMER indicator blinks.
Use remote control to retrieve error code.
1
Press for
5 seconds
3
Press for
5 seconds
to quit
checking
• For certain errors, you may restart the unit for limited
operation with 4 beeps when operation starts.
Cause
Check
2
Press until you
hear beep sound,
ON
ON
SET
SET
then write down
TIMER
TIMER
the error code
OFF
OFF
CANCEL
CANCEL
4
Turn the unit off
and reveal the
error code to
authorised dealer