Dometic GROUP Waeco CoolBreeze CB-1200-AC Instrucciones De Uso página 35

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
_BA_CB-1200.book Seite 35 Donnerstag, 16. Februar 2006 12:11 12
CB-1200
CoolBreeze CB-1200-AC/DC
Cooling capacity:
Fresh air supply:
Connection voltage:
Max. power consumption
at 230 V:
Start-up current:
Mean power consumption during
12 V operation:
Water consumption:
Absolute humidity:
Dimensions (W x H x D):
Weight:
Inverter
Output voltage:
Constant output:
Efficiency:
Dimensions (W x H x D):
Weight:
Testing/certification:
Versions, technical modifications and delivery options reserved.
E-tested according to 95/54/EG (EMC-/passenger car directive)
All manuals and user guides at all-guides.com
1200 to 2500 W (depending on
air humidity and ambient temperature)
Up to 400 m
230 V AC
Level 1 (night):
Level 2 (day):
< 1.5 A
Level 1: 13 A
Level 2: 22 A
0.5 – 1.5 l/h
No change in the interior
670 x 295 x 1298 mm
Approx. 23.5 kg
230 V
300 W
Up to 90 %
111 x 65.4 x 243 mm
1.1 kg
Technical data
3
/h
approx. 120 W
approx. 230 W
35
Tabla de contenido
loading

Este manual también es adecuado para:

Waeco coolbreeze cb-1200-ac/dc

Tabla de contenido